Power Supplies (Search by Input)

Sort order

AEA

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 600 - 1000W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
600W
AEA600F 41x127x186mm [1.61x5x7.32 inches]
(without terminal block)
Convection/Forced air
800W
AEA800F 50x127x203.2mm [1.97x5x8 inches]
(without terminal block)
Convection/Forced air
1000W
AEA1000F 50x127x228.6mm [1.97x5x9 inches]
(without terminal block)
Convection/Forced air
Close

AME

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 400, 600, 800, 1200W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
400W
AME400F 89×41×257mm Forced cooling (internal fan)
600W
AME600F 89×41×257mm Forced cooling (internal fan)
800W
AME800F 127×41×257mm Forced cooling (internal fan)
1200W
AME1200F 127×41×257mm Forced cooling (internal fan)
Close

FETA

Rated Input: FETA2500BA/3000BA/3000BC AC170 - 264V 1Φ
FETA7000T AC170 - 264V 3Φ-3Wire
FETA7000ST AC300 - 480V 3Φ-4Wire
Rated Output Wattage: 2500W, 3000W, 7000W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
2500W
FETA2500BA 102x41x340mm [4.02x1.61x13.39 inches] Forced cooling (internal fan)
3000W
FETA3000BA 102x41x340mm [4.02x1.61x13.39 inches] Forced cooling (internal fan)
3000W
FETA3000BC 102x41x340mm [4.02x1.61x13.39 inches] Forced cooling (internal fan)
7000W
FETA7000T 388×43×475mm [15.28x1.69x18.70 inches] Forced cooling (internal fan)
7000W
FETA7000ST 388×43×475mm [15.28x1.69x18.70 inches] Forced cooling (internal fan)
Close

GHA

Rated Input: AC90 - 264V 1Φ
GHA700F AC85 - 264V 1Φ
Rated Output Wattage: 300 - 700W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GHA300F 76.2x35x127mm [3.0x1.4x5.0 inches] Convection, Forced air (Require external fan)
500W
GHA500F 76.2x35x127mm [3.0x1.4x5.0 inches] Convection, Forced air (Require external fan) , Conduction cooling
700W
GHA700F 76.2x38.1x127mm [3.0x1.5x5.0 inches] Convection, Forced air (Require external fan) , Conduction cooling
Close

GMA

Rated Input : AC85 - 264V 1Φ
Rated Output Wattage : 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GMA300F 50.8x37x101.6mm [2.0x1.5x4.0 inches] Forced air
(Require external fan)
Close

HCA

Rated Input: 180 - 528VAC 3Φ-3Wire
Rated Output Wattage: 3500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3500W
HCA3500TF 110×65×420mm [4.33×2.56×16.54 inches]
(without terminal block)
Conduction cooling
Close

HFA

Rated Input: 180 - 528VAC 3Φ-3Wire
Rated Output Wattage: 3500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3500W
HFA3500TF 110×41×468mm [4.33×1.61×18.43 inches]
(without terminal block)
Forced cooling (internal fan)
Close

LHA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 10 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
LHA10F 50×21.5×62.5mm [1.97x0.85x2.46 inches] Convection/Forced air *
15W
LHA15F 50×21.5×73.5mm [1.97x0.85x2.89 inches] Convection/Forced air *
30W
LHA30F 50x27x87.5mm [1.97x1.07x3.44 inches] Convection/Forced air *
50W
LHA50F 50x27x112mm [1.97x1.07x4.41 inches] Convection/Forced air *
75W
LHA75F 50x27x150mm [1.97x1.07x5.91 inches] Convection/Forced air *
100W
LHA100F 62x27x155mm [2.44x1.07x6.10 inches] Convection/Forced air *
150W
LHA150F 75x27x160mm [2.95x1.07x6.30 inches] Convection/Forced air *
300W
LHA300F 84x37x180mm [3.31x1.46x7.09 inches] Convection/Forced air *
Close

LHP

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 150 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
150W
LHP150F 75x27x160mm [2.95x1.07x6.30 inches] Convection/Forced air *
300W
LHP300F 84x37x180mm [3.31x1.46x7.09 inches] Convection/Forced air *
Close

PCA

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 300 - 1500W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
PCA300F 89×41×152mm [3.50x1.61x5.98 inches] (without terminal block and screw) Forced cooling (internal fan)
600W
PCA600F 89×41×152mm [3.50x1.61x5.98 inches] (without terminal block and screw) Forced cooling (internal fan)
1000W
PCA1000F 102×41×178mm [4.02x1.61x7.01 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PCA1500F 140×41×203mm [5.52x1.61x7.99 inches] (without terminal block and screw) Forced cooling (internal fan)
Close

PDA

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 15 - 50W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PDA15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PDA30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PDA50F 31x82x120mm [1.22x3.23x4.72 inches] (without terminal block) Convection
Close

PJMA

Rated Input:AC85 ~ 264V 1Φ
Rated Output Wattage:300W, 600W, 1000W, 1500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
PJMA300F 102x41x190mm [4.02x1.61x7.48 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
600W
PJMA600F 120x61x215mm [4.72x2.40x8.46 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
1000W
PJMA1000F 150x61x240mm [5.91x2.40x9.45 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
1500W
PJMA1500F 178x61x268mm [7.01x2.40x10.55 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
Close

TECS

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 45 - 65W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
45W
TECS45F 25.4×23.5×76.2㎜ [1.00x0.93x3.00 inches] Convection/Forced air *
65W
TECS65F 25.4×27.0×76.2㎜ [1.00x1.06x3.00 inches] Convection/Forced air *
Close

TEPS

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 45 - 65W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
45W
TEPS45F 25.4×24.0×58.5㎜ [1.00x0.94x2.30 inches] Convection/Forced air *
65W
TEPS65F 25.4×27.5×58.5㎜ [1.00x1.08x2.30 inches] Convection/Forced air *
Close

TUNS

Rated Input: AC85 - 264V
TUNS1200F AC85 ~ 305V
Rated Output Wattage: 50 - 1200W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
TUNS50F 58.4x12.7x37.3mm [2.3x0.5x1.47 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
TUNS100F 58.4x12.7x61.0mm [2.3x0.5x2.4 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
300W
TUNS300F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
500W
TUNS500F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
700W
TUNS700F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
700W
TUNS700F-P 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
1200W
TUNS1200F 117.3x12.7x86.8mm [4.62x0.5x3.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

UMA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 30 - 60W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
30W
UMA30F 50.8×21.7×76.2mm Convection
60W
UMA60F 50.8×24.2×76.2mm Convection
Close

UMCS

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 30 - 60W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
30W
UMCS30F 55.9×35.7×109.2mm Convection
60W
UMCS60F 55.9×35.7×109.2mm Convection
Close

UMPS

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 30 - 60W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
30W
UMPS30F 55.9×30.5×81.3mm Convection
60W
UMPS60F 55.9×30.5×81.3mm Convection
Close

WBA

Rated Input: AC170 - 305 1Φ
Rated Output Wattage: 35 - 350W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
35W
WBA35B 30×82×99mm Convection
75W
WBA75B 30×97×99mm Convection
150W
WBA150B 30×97×159mm Convection
350W
WBA350B 115×30×215mm Forced cooling (internal fan)
Close

WDA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 30 - 90W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
30W
WDA30F 32x90x90mm [1.26x3.54x3.54 inches] Convection
60W
WDA60F 32x90x90mm [1.26x3.54x3.54 inches] Convection
90W
WDA90F 50x90x90mm [1.97x3.54x3.54 inches] Convection
Close

WMA

Rated Input: AC85 - 264 1Φ
Rated Output Wattage: 35 - 100W
Rated Input: AC85 - 132 1Φ/AC170 - 264 1Φ(Selectable by switch)
Rated Output Wattage: 150 - 350W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
35W
WMA35F 30×82×99mm Convection
75W
WMA75F 30×97×99mm Convection
100W
WMA100F 30×97×129mm Convection
150W
WMA150H 30×97×159mm Convection
350W
WMA350H 115×30×215mm Forced cooling (internal fan)
Close

ACE
To be discontinued by (October, 2025)

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 300 - 900W
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
ACE300F 103x63.5x254mm [4.06x2.5x10 inches] Forced cooling (built-in)
450W
ACE450F 127x63.5x254mm [5x2.5x10 inches] Forced cooling (built-in)
650W
ACE650F 127x63.5x279mm [5x2.5x10.98 inches] Forced cooling (built-in)
900W
ACE900F 177.5x63.5x254mm [6.99x2.5x10 inches] Forced cooling (built-in)
Close

DPF

Rated Input: AC85 - 264V, AC170 - 264V
Rated Output Wattage: 1000 - 1500W
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
1000 ~ 1500W
DPF1000 118.6x12.7x85mm [4.67x0.5x3.35 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

DPG

Rated Input: AC85 - 264V, AC170 - 264V
Rated Output Wattage: 300 - 750W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300 ~ 500W
DPG500 58.4x12.7x61mm [2.3x0.5x2.4 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
500 ~ 750W
DPG750 58.4x12.7x61mm [2.3x0.5x2.4 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

GHA-SNF

Rated Input: AC90 - 264V 1Φ
Rated Output Wattage: 300 - 500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GHA300F-SNF 85.2x41x165.3mm [3.35x1.61x6.5 inches] Forced air
500W
GHA500F-SNF 85.2x41x165.3mm [3.35x1.61x6.5 inches] Forced air
Close

KH

Rated Input: AC85 - 264V 1Φ/DC88 - 370V(Depends on model)
Rated Output Wattage: 30 - 480W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
30W
KHEA30F 22.5x75x90mm [0.89x2.95x3.54 inches] Convection
60W
KHEA60F 32x90x90mm [1.26x3.54x3.54 inches] Convection
90W
KHEA90F 50x90x90mm [1.97x3.54x3.54 inches] Convection
120W
KHEA120F 37x124x117mm [1.46x4.88x4.61 inches] Convection
240W
KHEA240F 50x124x117mm [1.97x4.88x4.61 inches] Convection
480W
KHEA480F 70x124x117mm [2.76x4.88x4.61 inches] Convection
30W
KHNA30F 22.5x75x90mm [0.89x2.95x3.54 inches] Convection
60W
KHNA60F 32x90x90mm [1.26x3.54x3.54 inches]
Convection
90W
KHNA90F 50x90x90mm [1.97x3.54x3.54 inches] Convection
120W
KHNA120F 37x124x117mm [1.46x4.88x4.61 inches] Convection
240W
KHNA240F 50x124x117mm [1.97x4.88x4.61 inches] Convection
480W
KHNA480F 70x124x117mm [2.76x4.88x4.61 inches] Convection
Close

KL

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 120, 240W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
120W
KLEA120F 38x124x117mm [1.5x4.88x4.61 inches] Convection
240W
KLEA240F 50x124x117mm [1.97x4.88x4.61 inches] Convection
120W
KLNA120F 38x124x117mm [1.5x4.88x4.61 inches] Convection
240W
KLNA240F 50x124x117mm [1.97x4.88x4.61 inches] Convection
Close

KR

Redundancy module
Rated Input: DC10 - 30V, DC10 - 60V
Rated Output Current: 20,40A
RoHS ECO Model
Product Line-up

Output Voltage/Current Model Dimensions Cooling Method
10 - 60V 20A
KRE-20A 38x124x117mm [1.5x4.88x4.61 inches] Convection
10 - 30V 40A
KRE-40A 38x124x117mm [1.5x4.88x4.61 inches] Convection
Close

LFA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 10 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
LFA10F 50x22x73.5mm [1.97x0.87x2.89 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
15W
LFA15F 50x22x87.5mm [1.97x0.87x3.44 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
30W
LFA30F 50x26.5x105mm [1.97x1.04x4.13 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
50W
LFA50F 50x26.5x132mm [1.97x1.04x5.20 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
75W
LFA75F 50x33.5x150mm [1.97x1.32x5.91 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
100W
LFA100F 62x33.5x155mm [2.44x1.32x6.10 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
150W
LFA150F 75x37.0x160mm [2.95x1.46x6.30 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
240W
LFA240F 84x46.5x180mm [3.31x1.83x7.09 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
300W
LFA300F 95x52.5x222mm [3.74x2.07x8.74 inches] Convection/Forced air (Refer to Instruction Manual 3.1 and 3.2) *
Close

LFP

Rated Input:AC85 - 264V 1Φ
Rated Output Wattage:100 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
100W
LFP100F 62x33x155mm [2.44x1.30x6.10 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
150W
LFP150F 75x36.5x160mm [2.95x1.44x6.30 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
240W
LFP240F 84x46x180mm [3.31x1.81x7.09 inches] Convection/Forced air *
300W
LFP300F 95x52.5x222mm [3.74x2.07x8.74 inches] (without terminal block) Convection/Forced air *
Close

LGA

Rated Input: AC85 - 132V 1Φ
Rated Output Wattage: 50 - 240W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
LGA50A 50x28.5x132mm [1.97x1.12x5.2 inches] Convection (Refer to Instruction Manual 3.2)
75W
LGA75A 50x34.5x150mm [1.97x1.36x5.91 inches] Convection (Refer to Instruction Manual 3.2)
100W
LGA100A 62x35.5x155mm [2.44x1.4x6.1 inches] Convection (Refer to Instruction Manual 3.2)
150W
LGA150A 75x39x160mm [2.95x1.54x6.3 inches] Convection (Refer to Instruction Manual 3.2)
240W
LGA240A 84x48.5x180mm [3.31x1.91x7.09 inches] Convection (Refer to Instruction Manual 3.2)
Close

LMA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 100 - 240W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
100W
LMA100F 62x33x155mm [2.44x1.30x6.10 inches] Convection *
150W
LMA150F 75x36.5x160mm [2.95x1.44x6.30 inches] Convection *
240W
LMA240F 84x46x180mm [3.31x1.81x7.09 inches] Convection/Forced air *
Close

PBA

Rated Input: AC85 - 264V 1Φ
PBA1500T AC170 - 264V 3Φ
Rated Output Wattage: 10 - 1500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
PBA10F 31x78x68mm [1.22x3.07x2.68 inches] (without terminal block) Convection
15W
PBA15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PBA30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PBA50F 31x82x120mm [1.22x3.23x4.72 inches] (without terminal block) Convection
75W
PBA75F 32x82x135mm [1.26x3.23x5.31 inches] (without terminal block) Convection
100W
PBA100F 32x93x147mm [1.26x3.66x5.79 inches] (without terminal block) Convection
150W
PBA150F 34x93x168mm [1.34x3.66x6.61 inches] (without terminal block) Convection
300W
PBA300F 102x42x170mm [4.02x1.65x6.69 inches] (without terminal block and screw) Forced cooling (internal fan)
600W
PBA600F 120x61x190mm [4.72x2.4x7.48 inches] (without terminal block and screw) Forced cooling (internal fan)
1000W
PBA1000F 150x61x240mm [5.91x2.4x9.45 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PBA1500F 178x61x268mm [7.01x2.4x10.55 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PBA1500T 178x61x268mm [7.01x2.4x10.55 inches] (without terminal block and screw) Forced cooling (internal fan)
Close

PBW

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 15 - 50W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PBW15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PBW30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PBW50F 31x82x120mm [1.22x3.23x4.72 inches] Convection
Close

PJA

Rated Input:AC85 ~ 264V 1Φ
Rated Output Wattage:100W, 150W, 300W, 600W, 1000W, 1500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
100W
PJA100F 41x97x109mm [1.61x3.82x4.29 inches] (Excluding terminal block and screw) Convection
150W
PJA150F 41x97x129mm [1.61x3.82x5.08 inches] (Excluding terminal block and screw) Convection
300W
PJA300F 102x41x190mm [4.02x1.61x7.48 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
600W
PJA600F 120x61x215mm [4.72x2.40x8.46 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
1000W
PJA1000F 150x61x240mm [5.91x2.40x9.45 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
1500W
PJA1500F 178x61x268mm [7.01x2.40x10.55 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
Close

PLA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 15 - 600W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PLA15F 38x80x73mm [1.50x3.15x2.87 inches] (Excluding terminal block and screw) Convection
30W
PLA30F 38x80x88mm [1.50x3.15x3.46 inches] (Excluding terminal block and screw) Convection
50W
PLA50F 38x80x99mm [1.50x3.15x3.90 inches] (Excluding terminal block and screw) Convection
100W
PLA100F 41x97x109mm [1.61x3.82x4.29 inches] (Excluding terminal block and screw) Convection
150W
PLA150F 41x97x129mm [1.61x3.82x5.08 inches] (Excluding terminal block and screw) Convection
300W
PLA300F 102x41x190mm [4.02x1.61x7.48 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
600W
PLA600F 120x61x215mm [4.72x2.40x8.46 inches] (Excluding terminal block and screw) Forced cooling (internal fan)
Close

PMA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 15 - 100W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PMA15F 31x78x103mm [1.22x3.07x4.06 inches] Convection
30W
PMA30F 31x82x120mm [1.22x3.23x4.72 inches] Convection
60W
PMA60F 32x82x135mm [1.26x3.23x5.31 inches] Convection
100W
PMA100F 34x93x168mm [1.34x3.66x6.61 inches] Convection
Close

SC

Rated Input: AC170 - 264V 3Φ
Rated Output Wattage: 10000W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10000W
SCHA10000T 459x150x320mm [18.07x5.91x12.6 inches] Forced cooling (require external fan)
10000W
SCDA10000T 310.5x150x510mm [12.22x5.91x20.08 inches] Forced cooling (require external fan)
Close

SNDPF

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 1000W
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
1000 ~ 1500W
SNDPF1000 127x44.5x222mm [5.0x1.75x8.75 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNDPG

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 750W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
500 ~ 750W
SNDPG750 125x44.5x127mm [4.92x1.75x5.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNTU

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 50 - 100W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
SNTUNS50F 50x36x150mm [1.97x1.42x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
SNTUNS100F 74x37x150mm [2.91x1.46x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

TUHS

Rated Input: AC85 - 264V, DC120 - 370V
Rated Output Wattage: 3 - 25W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3W
TUHS3F 28.7x12.7x17.5mm [1.13x0.50x0.69 inches] Convection/Forced air
5W
TUHS5F 28.7x12.7x17.5mm [1.13x0.50x0.69 inches] Convection/Forced air
10W
TUHS10F 33.0x15.0x22.0mm [1.3x0.59x0.86 inches] Convection/Forced air
15W
TUHS15F 33.0x15.0x22.0mm [1.3x0.59x0.86 inches] Convection/Forced air
25W
TUHS25F 36.0x16.5x25.4mm [1.42x0.65x1.0 inches] Convection/Forced air
Close

TUXS

Rated Input: AC85 - 264V
Rated Output Wattage: 150W, 200W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
150W
TUXS150F 76.2x28.5x50.8mm [3.0x1.12x2.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
200W
TUXS200F 76.2x28.5x50.8mm [3.0x1.12x2.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.