PCA1500F

Released 2021

Features of PCA1500F

• Low profile (41mm, 1.61inch = meet 1U height)
• For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 12V 0.1A (Voltage variable range 5 - 12V)
• Constant current function
• Output voltage can be adjusted to near 0V
• With various alarms
• Parallel Operation / N+1 Parallel Redundancy Operation possible
• Monitoring function and various setting values can be changed by communication
•Complies with SEMI F-47(Io:100%max at ACIN 200V, 70%max at ACIN 100V)

Ordering Information and Options

PC(1) A(2) 1500(3) F(4) - (5) - (6) 


(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating
  G: Low leakage current
  I: with PMBus interface
  F2: Reverse air exhaust type
  P3: Master-slave Operation
  W1: Alarm function
For option details, refer to instruction manual 6.1.
3D product images are available.

Read Me First
Standard model (Bus bar)

Recommended EMI Filters

Product Line-up

Product Name Output Wattage Output Voltage・Current
PCA1500F-5 1500W 5V 300A
PCA1500F-12 1500W 12V 125A
PCA1500F-15 1500W 15V 100A
PCA1500F-24 1560W ACIN100V
1680W ACIN230V
24V 65A ACIN100V
24V 70A ACIN230V
PCA1500F-32 1504W ACIN100V
1664W ACIN230V
32V 47A ACIN100V
32V 52A ACIN230V
PCA1500F-48 1536W ACIN100V
1680W ACIN230V
48V 32A ACIN100V
48V 35A ACIN230V
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Optional Parts

Category Part Number Description PDF DXF
Harness
H-PA-14 Harness for serial operation. -
H-PA-15 Harness for parallel operation and N+1 parallel redundancy operation. -
H-PA-16 Harness for parallel operation of mater-slave. -
H-SN-48 Harness for using all functions of CN1 and CN2. -
H-SN-49 Harness for using all functions except remote sensing of CN1 and CN2. -
H-SN-50 Harness for using all functions of CN3. -
H-SN-51 Harness for using all functions of CN4. -
H-SN-52 Harness for using example remote ON/OFF circuit C. -
H-SN-53 Harness for using in slave setting of mater-slave operation. -
H-SN-54 Harness for using in effective setting of external output voltage adjustment. -
H-SN-66 Harness for using PMBus communication(for -I option). -
Communication converter
CR-PC-1 This is a unit to convert Extended UART signal to RS232 signal mutually. -
CR-PC-2 This is a unit to convert Extended UART signal to RS485(Modbus-RTU) signal mutually. -
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.