Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 800W
Output Voltage: 24V, 30V, 36V, 48V
Rated Output Wattage: 800W
Output Voltage: 24V, 30V, 36V, 48V
Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of AEA800F
• Single output with triple peak current• High efficiency
• Low profile (50mm)
• Medical Isolation Grade 2MOPP (Suitable for BF application)
• Meets EN62477-1 OVCⅢ
• Complies with SEMI F47
• Meets UL508 (Option: -T5. Except 30V)
Ordering Information and Options
AE(1) A(2) 800(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
N: with Cover
T: Vertical terminal block
J: Connector type
R3: with Subfeatures (5V AUX, 12V AUX, Remote, Alarm function)
I4: with MODBUS interface and Subfeatures (5V AUX, 12V AUX, Remote, Alarm function)
T5: UL508 (Except 30V)
P5: Overcurrent protection to shut down the output.
Specification is changed at option, refer to Instruction Manual.
3D product images are available.
Read Me First
Standard N: with Cover T: Vertical terminal block J: Connector type
Recommended EMI Filters
Product Line-up
Product Name | Output Wattage | Output Voltage・Current |
---|---|---|
AEA800F-24 |
564.0W (Peak: 1740W) 230VAC, Convection Cooling 816.0W (Peak: 1740W) 230VAC, Forced Air Cooling |
24V, 23.5A (Peak: 72.5A) 230VAC, Convection Cooling 24V, 34.0A (Peak: 72.5A) 230VAC, Forced Air Cooling |
AEA800F-30 |
564.0W (Peak: 1740W) 230VAC, Convection Cooling 816.0W (Peak: 1740W) 230VAC, Forced Air Cooling |
30V, 18.8A (Peak: 58.0A) 230VAC, Convection Cooling 30V, 27.2A (Peak: 58.0A) 230VAC, Forced Air Cooling |
AEA800F-36 |
565.2W (Peak: 1742W) 230VAC, Convection Cooling 817.0W (Peak: 1742W) 230VAC, Forced Air Cooling |
36V, 15.7A (Peak: 48.4A) 230VAC, Convection Cooling 36V, 22.7A (Peak: 48.4A) 230VAC, Forced Air Cooling |
AEA800F-48 |
566.4W (Peak: 1742W) 230VAC, Convection Cooling 816.0W (Peak: 1742W) 230VAC, Forced Air Cooling |
48V, 11.8A (Peak: 36.3A) 230VAC, Convection Cooling 48V, 17.0A (Peak: 36.3A) 230VAC, Forced Air Cooling |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Optional Parts
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-IN-11 | Mating harness for input of the connector type power supply. (J option) | - | |
H-OU-53 | Mating harness for output with J option. | - | ||
H-PA-17 | Harness for parallel operation. | - | ||
H-SN-39 | Harness for using functions of CN4 (option: -I4) . | - | ||
H-SN-71 | Harness for using functions of CN3 (option:-R3 and -I4) . | - |