PCA1000F

Released 2019
Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 1000W
Rated Output Voltage:5V,12V,15V,24V,32V,48V
 
RoHS ECO MODEL
UL・C-UL DEMKO CE
Warranty Period 5-year (Refer to Instruction Manuals)

• Low profile (41mm, 1.61inch=meet to 1U height)

Features of PCA1000F

• Low profile (41mm, 1.61inch=meet to 1U height)
• Universal input 85 - 264VAC
• Output derating required (85V - 90VAC)
• For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 12V 0.1A (Voltage variable range 5 - 12V)
• Constant current regulation
• Output voltage can be varied to near 0V
• With various alarms
• Parallel operation possible
• N+1 Parallel Redundancy Operation possible
• Monitoring function by communication and various setting values can be changed

Ordering Information and Options

PC(1) A(2) 1000(3) F(4) - (5) - (6) 



(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating
  G: Low leakage current
  T: Terminal Block Style
    (Only 24V,32V and 48V)
  I: with PMBus interface
  F2: Reverse Fan direction
  P3: Master/slave operation
  W1: Alarm specification
For option details, refer to instruction manual 7.1.

Recommended EMI Filters

Product Line-up

Product Name Output Wattage Output Voltage・Current
PCA1000F-5 1000W 5V 200A
PCA1000F-12 1056W 12V 88A
PCA1000F-15 1050W 15V 70A
PCA1000F-24 1056W 24V 44A
PCA1000F-32 1056W 32V 33A
PCA1000F-48 1056W 48V 22A
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Optional Parts

Category Part Number Description PDF DXF
Harness
H-PA-14 Harness for serial operation. -
H-PA-15 Harness for parallel operation and N+1 parallel redundancy operation. -
H-SN-48 Harness for using all functions of CN1 and CN2. -
H-SN-49 Harness for using all functions except remote sensing of CN1 and CN2. -
H-SN-50 Harness for using all functions of CN3. -
H-SN-51 Harness for using all functions of CN4. -
H-SN-52 Harness for using example remote ON/OFF circuit C. -
H-SN-53 Harness for using in slave setting of mater-slave operation. -
H-SN-54 Harness for using in effective setting of external output voltage adjustment. -