Power Supplies (Search by Industry・Application)

Sort order

GHA

Rated Input: AC90 - 264V 1Φ
GHA700F AC85 - 264V 1Φ
Rated Output Wattage: 300 - 700W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GHA300F 76.2x35x127mm [3.0x1.4x5.0 inches] Convection, Forced air (Require external fan)
500W
GHA500F 76.2x35x127mm [3.0x1.4x5.0 inches] Convection, Forced air (Require external fan) , Conduction cooling
700W
GHA700F 76.2x38.1x127mm [3.0x1.5x5.0 inches] Convection, Forced air (Require external fan) , Conduction cooling
Close

GMA

Rated Input : AC85 - 264V 1Φ
Rated Output Wattage : 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GMA300F 50.8x37x101.6mm [2.0x1.5x4.0 inches] Forced air
(Require external fan)
Close

LHA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 10 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
LHA10F 50×21.5×62.5mm [1.97x0.85x2.46 inches] Convection/Forced air *
15W
LHA15F 50×21.5×73.5mm [1.97x0.85x2.89 inches] Convection/Forced air *
30W
LHA30F 50x27x87.5mm [1.97x1.07x3.44 inches] Convection/Forced air *
50W
LHA50F 50x27x112mm [1.97x1.07x4.41 inches] Convection/Forced air *
75W
LHA75F 50x27x150mm [1.97x1.07x5.91 inches] Convection/Forced air *
100W
LHA100F 62x27x155mm [2.44x1.07x6.10 inches] Convection/Forced air *
150W
LHA150F 75x27x160mm [2.95x1.07x6.30 inches] Convection/Forced air *
300W
LHA300F 84x37x180mm [3.31x1.46x7.09 inches] Convection/Forced air *
Close

LHP

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 150 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
150W
LHP150F 75x27x160mm [2.95x1.07x6.30 inches] Convection/Forced air *
300W
LHP300F 84x37x180mm [3.31x1.46x7.09 inches] Convection/Forced air *
Close

MGFS

Rated Input: DC4.5 - 13V, DC9 - 36V, DC18 - 76V
Rated Output Wattage: 1.5 - 80W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGFS1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
3W
MGFS3 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGFS6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
10W
MGFS10 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
15W
MGFS15 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
30W
MGFS30 25.4x9.9x50.8mm [1x0.39x2 inches] Convection/Forced air
40W
MGFS40 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
80W
MGFS80 25.4x9.9x50.8mm [1x0.39x2 inches] Convection/Forced air
Close

MGFW

Rated Input: DC4.5 - 13V, DC9 - 36V, DC18 - 76V
Rated Output Wattage: 1.5 - 80W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGFW1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
3W
MGFW3 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGFW6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
10W
MGFW10 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
15W
MGFW15 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
30W
MGFW30 25.4x9.9x50.8mm [1x0.39x2 inches] Convection/Forced air
40W
MGFW40 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
80W
MGFW80 25.4x9.9x25.4mm [1x0.39x2 inches] Convection/Forced air
Close

MHFS

Rated Input: 4.5 - 18VDC, 9 - 36VDC, 18 - 76VDC
Rated Output Wattage: 3W, 6W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3W
MHFS3 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
6W
MHFS6 26.0x12.0x9.5mm [1.03x0.48x0.38 inches] Convection/Forced air
Close

MHFW

Rated Input: 4.5 - 18VDC, 9 - 36VDC, 18 - 76VDC
Rated Output Wattage: 3W, 6W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3W
MHFW3 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
6W
MHFW6 26.0x12.0x9.5mm [1.03x0.48x0.38 inches] Convection/Forced air
Close

PCA

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 300 - 1500W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
PCA300F 89×41×152mm [3.50x1.61x5.98 inches] (without terminal block and screw) Forced cooling (internal fan)
600W
PCA600F 89×41×152mm [3.50x1.61x5.98 inches] (without terminal block and screw) Forced cooling (internal fan)
1000W
PCA1000F 102×41×178mm [4.02x1.61x7.01 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PCA1500F 140×41×203mm [5.52x1.61x7.99 inches] (without terminal block and screw) Forced cooling (internal fan)
Close

PDA

Rated Input: 85 - 264VAC 1Φ
Rated Output Wattage: 15 - 50W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PDA15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PDA30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PDA50F 31x82x120mm [1.22x3.23x4.72 inches] (without terminal block) Convection
Close

STMGFS

Rated Input: DC9 - 36V, DC18 - 76V
Rated Output Wattage: 15 - 80W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
STMGFS15 52x27x93mm [2.05x1.06x3.66 inches] Convection/Forced air
30W
STMGFS30 52x27x117mm [2.05x1.06x4.61 inches] Convection/Forced air
80W
STMGFS80 52x29x117mm [2.05x1.14x4.61 inches] Convection/Forced air
Close

TUNS

Rated Input: AC85 - 264V
TUNS1200F AC85 ~ 305V
Rated Output Wattage: 50 - 1200W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
TUNS50F 58.4x12.7x37.3mm [2.3x0.5x1.47 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
TUNS100F 58.4x12.7x61.0mm [2.3x0.5x2.4 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
300W
TUNS300F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
500W
TUNS500F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
700W
TUNS700F 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
700W
TUNS700F-P 117.3x12.7x61.5mm [4.62x0.5x2.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
1200W
TUNS1200F 117.3x12.7x86.8mm [4.62x0.5x3.42 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

BRDS

Rated Input: DC4.5 - 14.0V
Rated Output Current : 40 - 150A
RoHS ECO Model PMBus
Product Line-up

Output Voltage/Current Model Dimensions Cooling Method
1.2V 40.0A
BRDS40 33.0x10.9x13.5mm [1.3x0.43x0.53 inches] Convection/Forced air
1.2V 60.0A
BRDS60 33.0x8.0x22.9mm [1.3x0.31x0.9 inches] Convection/Forced air
1.2V 60.0A
BRDS60S 33.0x12.7x13.5mm [1.3x0.5x0.53 inches] Convection/Forced air
1.2V 100.0A
BRDS100 38.0x8.5x27.7mm [1.5x0.33x1.09 inches] Convection/Forced air
1.2V 120.0A
BRDS120 33.0x12.7x22.9mm [1.3x0.5x0.9 inches] Convection/Forced air
1.2V 150.0A
BRDS150 38.0x13.8x27.7mm [1.5x0.54x1.09 inches] Convection/Forced air
Close

BRFS

Rated Input: DC4.5 - 14.0V
Rated Output Current : 30 - 150A

*BRFS50,BRFS50L models to discontinued
Alternative model:BRFS60
(November, 2019)
RoHS ECO Model
Product Line-up

Output Voltage/Current Model Dimensions Cooling Method
1.2V 30.0A
BRFS30 33.0x9.5x13.5mm [1.3x0.37x0.53 inches] Convection/Forced air
1.2V 40.0A
BRFS40 33.0x10.9x13.5mm [1.3x0.43x0.53 inches] Convection/Forced air
1.2V 60.0A
BRFS60 33.0x8.0x22.9mm [1.3x0.31x0.9 inches] Convection/Forced air
1.2V 60.0A
BRFS60S 33.0x12.7x13.5mm [1.3x0.5x0.53 inches] Convection/Forced air
1.2V 100.0A
BRFS100 38.0x8.5x27.7mm [1.5x0.33x1.09 inches] Convection/Forced air
1.2V 120.0A
BRFS120 33.0x12.7x22.9mm [1.3x0.5x0.9 inches] Convection/Forced air
1.2V 150.0A
BRFS150 38.0x13.8x27.7mm [1.5x0.54x1.09 inches] Convection/Forced air
Close

BRNS

Rated Input: DC3.0 - 14.4V
Rated Output Current : 6 - 20A
RoHS ECO Model
Product Line-up

Output Voltage/Current Model Dimensions Cooling Method
1.2V 6.0A
BRNS6 12.2x7.2x12.2mm [0.48x0.28x0.48 inches] Convection/Forced air
1.2V 12.0A
BRNS12 12.2x7.2x12.2mm [0.48x0.28x0.48 inches] Convection/Forced air
1.2V 20.0A
BRNS20 20.3x8.5x11.4mm [0.80x0.35x0.45 inches] Convection/Forced air
Close

CHS

Rated Input:DC18 - 36V, DC36 - 76V
Rated Output Wattage:60 - 700W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
60W
CHS60 19.05x12.7x23.36mm [0.75x0.5x0.92 inches] Convection/Forced air
80W
CHS80 33.0x10.5x22.76mm [1.3x0.41x0.9 inches] Convection/Forced air
120W
CHS120 33.0x10.5x22.86mm [1.3x0.41x0.9 inches]
33.5x12.7x23.36mm [1.32x0.5x0.92 inches] * (BasePlate Option)
36.5x12.7x26.5mm [1.44x0.5x1.04 inches] * (BasePlate and case Option)
Convection/Forced air/Conduction
200W
CHS200 57.9x10.5x22.76mm [2.28x0.41x0.9 inches]
58.4x12.7x23.26mm [2.3x0.5x0.92 inches] * (BasePlate Option)
Convection/Forced air/Conduction
300W
CHS300 58.4x11.0x22.86mm [2.3x0.43x0.9 inches]
58.9x12.7x23.3mm [2.32x0.5x0.92 inches] * (*BasePlate Option)
61.1X14.3X26.1 [2.41X0.56X1.03inches] ** (**Baseplate and case option)
Convection/Forced air/Conduction
380W
CHS380 58.4x11.0x22.86mm [2.3x0.43x0.9 inches]
58.9x12.7x23.26mm [2.32x0.5x0.92 inches] * (BasePlate Option)
Convection/Forced air/Conduction
400W
CHS400 58.4x9.5x36.8mm [2.3x0.37x1.45 inches]
58.9x12.7x37.3mm [2.32x0.5x1.47 inches] * (Baseplate option)
61.6x12.7x40.3mm [2.43x0.5x1.59 inches] * (Baseplate and case option)
Convection/Forced air/Conduction
500W
CHS500 58.4x9.5x36.8mm [2.3x0.37x1.45 inches]
58.9x12.7x37.3mm [2.32x0.5x1.47 inches] * (BasePlate Option)
Convection/Forced air/Conduction
700W
CHS700 58.4x10.5x36.8mm [2.3x0.41x1.45 inches]
58.9x12.7x37.3mm [2.32x0.5x1.47 inches] * (BasePlate Option)
Convection/Forced air/Conduction
Close

CQHS

Rated Input: DC36 - 76V *
Rated Output Wattage: 250 - 350W
*Input voltage range depends on model
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
250W
CQHS250 57.9x10.5x22.76mm [2.28x0.41x0.9 inches]
58.4x12.7x23.26mm [2.3x0.5x0.92 inches]*(BasePlate Option)
Convection/Forced air/Conduction
300W
CQHS300 57.9x12.7x36.8mm [2.28x0.5x1.45 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
350W
CQHS350 57.9x12.7x36.8mm [2.28x0.5x1.45 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

DBS

Rated Input: DC45 - 160V, DC66 - 160V, DC200 - 400V
Rated Output Wattage: 100 - 700W
*DBS100A/150A models to discontinued(May,2023)
*DBS200B/400B models to discontinued(Nov,2023)
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
700W
DBS700B 61x12.7x116.8mm [2.4x0.5x4.6 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

DHS

Rated Input: DC60 - 160V, DC200 - 400V
Rated Output Wattage: 50 - 250W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
DHS50B 58.4x12.7x37.3mm [2.3x0.5x1.47 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
DHS100B 58.4x12.7x37.3mm [2.3x0.5x1.47 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
250W
DHS250B 58.4x12.7x61.0mm [2.3x0.5x2.4 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

GHA-SNF

Rated Input: AC90 - 264V 1Φ
Rated Output Wattage: 300 - 500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
300W
GHA300F-SNF 85.2x41x165.3mm [3.35x1.61x6.5 inches] Forced air
500W
GHA500F-SNF 85.2x41x165.3mm [3.35x1.61x6.5 inches] Forced air
Close

LFA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 10 - 300W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
LFA10F 50x22x73.5mm [1.97x0.87x2.89 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
15W
LFA15F 50x22x87.5mm [1.97x0.87x3.44 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
30W
LFA30F 50x26.5x105mm [1.97x1.04x4.13 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
50W
LFA50F 50x26.5x132mm [1.97x1.04x5.20 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
75W
LFA75F 50x33.5x150mm [1.97x1.32x5.91 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
100W
LFA100F 62x33.5x155mm [2.44x1.32x6.10 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
150W
LFA150F 75x37.0x160mm [2.95x1.46x6.30 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
240W
LFA240F 84x46.5x180mm [3.31x1.83x7.09 inches] Convection (Refer to Instruction Manual 3.1 and 3.2) *
300W
LFA300F 95x52.5x222mm [3.74x2.07x8.74 inches] Convection/Forced air (Refer to Instruction Manual 3.1 and 3.2) *
Close

LGA

Rated Input: AC85 - 132V 1Φ
Rated Output Wattage: 50 - 240W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
LGA50A 50x28.5x132mm [1.97x1.12x5.2 inches] Convection (Refer to Instruction Manual 3.2)
75W
LGA75A 50x34.5x150mm [1.97x1.36x5.91 inches] Convection (Refer to Instruction Manual 3.2)
100W
LGA100A 62x35.5x155mm [2.44x1.4x6.1 inches] Convection (Refer to Instruction Manual 3.2)
150W
LGA150A 75x39x160mm [2.95x1.54x6.3 inches] Convection (Refer to Instruction Manual 3.2)
240W
LGA240A 84x48.5x180mm [3.31x1.91x7.09 inches] Convection (Refer to Instruction Manual 3.2)
Close

LMA

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 100 - 240W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
100W
LMA100F 62x33x155mm [2.44x1.30x6.10 inches] Convection *
150W
LMA150F 75x36.5x160mm [2.95x1.44x6.30 inches] Convection *
240W
LMA240F 84x46x180mm [3.31x1.81x7.09 inches] Convection/Forced air *
Close

MGS

Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V
Rated Output Wattage: 1.5 - 30W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGS1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
3W
MGS3 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGS6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
10W
MGS10 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
15W
MGS15 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
30W
MGS30 25.4x9.9x50.8mm [1x0.39x2 inches] Convection/Forced air
Close

MGW

Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V
Rated Output Wattage: 1.5 - 30W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGW1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
3W
MGW3 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGW6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
10W
MGW10 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
15W
MGW15 25.4x9.9x25.4mm [1x0.39x1 inches] Convection/Forced air
30W
MGW30 25.4x9.9x50.8mm [1x0.39x2 inches] Convection/Forced air
Close

MGXS

Rated Input: DC6 - 60V
Rated Output Wattage: 1.5W, 6W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGXS1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGXS6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
Close

MGXW

Rated Input: DC6 - 60V
Rated Output Wattage: 1.5W, 6W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
1.5W
MGXW1R5 17.0x12.0x8.5mm [0.67x0.48x0.34 inches] Convection/Forced air
6W
MGXW6 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] Convection/Forced air
Close

PBA

Rated Input: AC85 - 264V 1Φ
PBA1500T AC170 - 264V 3Φ
Rated Output Wattage: 10 - 1500W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
10W
PBA10F 31x78x68mm [1.22x3.07x2.68 inches] (without terminal block) Convection
15W
PBA15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PBA30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PBA50F 31x82x120mm [1.22x3.23x4.72 inches] (without terminal block) Convection
75W
PBA75F 32x82x135mm [1.26x3.23x5.31 inches] (without terminal block) Convection
100W
PBA100F 32x93x147mm [1.26x3.66x5.79 inches] (without terminal block) Convection
150W
PBA150F 34x93x168mm [1.34x3.66x6.61 inches] (without terminal block) Convection
300W
PBA300F 102x42x170mm [4.02x1.65x6.69 inches] (without terminal block and screw) Forced cooling (internal fan)
600W
PBA600F 120x61x190mm [4.72x2.4x7.48 inches] (without terminal block and screw) Forced cooling (internal fan)
1000W
PBA1000F 150x61x240mm [5.91x2.4x9.45 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PBA1500F 178x61x268mm [7.01x2.4x10.55 inches] (without terminal block and screw) Forced cooling (internal fan)
1500W
PBA1500T 178x61x268mm [7.01x2.4x10.55 inches] (without terminal block and screw) Forced cooling (internal fan)
Close

PBW

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 15 - 50W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
PBW15F 31x78x85mm [1.22x3.07x3.35 inches] (without terminal block) Convection
30W
PBW30F 31x78x103mm [1.22x3.07x4.06 inches] (without terminal block) Convection
50W
PBW50F 31x82x120mm [1.22x3.23x4.72 inches] Convection
Close

SFCS
To be discontinued by (April, 2026)

Rated Input: DC18 - 36V, DC36 - 76V
Rated Output Wattage: 15 - 30W



*SFCS15/30 (48V input) models to discontinued(April,2025)
*SFCS15/30 (24V input) models to discontinued(April,2026)
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
SFCS15 39.1x6.8x29.5mm [1.54x0.268x1.16 inches] Convection
30W
SFCS30 39.3x8.8x33.5mm [1.55x0.347x1.32 inches] Convection/Forced air
Close

SFS
To be discontinued by (April, 2026)

Rated Input:DC18 - 36V, DC36 - 76V
Rated Output Wattage:10 - 30W

*Product names under 2.5v output to discontinued(May,2023)
*SFS10/20 models to discontinued(May,2024)
*SFS15/30 (48V input) models to discontinued(April,2025)
*SFS15/30 (24V input) models to discontinued(April,2026)
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
SFS15 38.7x5.0x27.2mm [1.52x0.197x1.07 inches] Convection
30W
SFS30 38.7x8.0x31.2mm [1.52x0.315x1.23 inches] Convection/Forced air
Close

SNDBS

Rated Input: DC200 - 400V
Rated Output Wattage: 400 - 700W
*SNDBS400B models to discontinued(Nov,2023)
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
700W
SNDBS700B 89x44.5x222mm [3.51x1.75x8.75 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNDHS

Rated Input: DC60 - 160V
Rated Output Wattage: 50 - 250W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
SNDHS50A 61.5x44.5x150mm [2.42x1.75x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
SNDHS100A 61.5x44.5x150mm [2.42x1.75x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
200W
SNDHS200A 74.2x44.5x150mm [2.92x1.75x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
50W
SNDHS50B 61.5x44.5x127mm[2.42x1.75x5.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
SNDHS100B 61.5x44.5x127mm[2.42x1.75x5.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
250W
SNDHS250B 74.2x44.5x127mm [2.92x1.75x5.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNDPF

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 1000W
RoHS
Product Line-up

Output Wattage Model Dimensions Cooling Method
1000 ~ 1500W
SNDPF1000 127x44.5x222mm [5.0x1.75x8.75 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNDPG

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 750W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
500 ~ 750W
SNDPG750 125x44.5x127mm [4.92x1.75x5.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

SNTU

Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 50 - 100W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
50W
SNTUNS50F 50x36x150mm [1.97x1.42x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
100W
SNTUNS100F 74x37x150mm [2.91x1.46x5.91 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close

STMGFW

Rated Input: DC9 - 36V, DC18 - 76V
Rated Output Wattage: 15 - 30W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
15W
STMGFW15 52x27x93mm [2.05x1.06x3.66xinches] Convection/Forced air
30W
STMGFW30 52x27x117mm [2.05x1.06x4.61 inches] Convection/Forced air
Close

TUHS

Rated Input: AC85 - 264V, DC120 - 370V
Rated Output Wattage: 3 - 25W
RoHS ECO Model
Product Line-up

Output Wattage Model Dimensions Cooling Method
3W
TUHS3F 28.7x12.7x17.5mm [1.13x0.50x0.69 inches] Convection/Forced air
5W
TUHS5F 28.7x12.7x17.5mm [1.13x0.50x0.69 inches] Convection/Forced air
10W
TUHS10F 33.0x15.0x22.0mm [1.3x0.59x0.86 inches] Convection/Forced air
15W
TUHS15F 33.0x15.0x22.0mm [1.3x0.59x0.86 inches] Convection/Forced air
25W
TUHS25F 36.0x16.5x25.4mm [1.42x0.65x1.0 inches] Convection/Forced air
Close

TUXS

Rated Input: AC85 - 264V
Rated Output Wattage: 150W, 200W
RoHS ECO Model PMBus
Product Line-up

Output Wattage Model Dimensions Cooling Method
150W
TUXS150F 76.2x28.5x50.8mm [3.0x1.12x2.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
200W
TUXS200F 76.2x28.5x50.8mm [3.0x1.12x2.0 inches] Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
Close
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.