ADA600F-48

Released 2003
RoHS
UL・C-UL TUV CE
Warranty Period 5-year (Refer to Instruction Manuals)

Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

Features of ADA600F-48

• High power & peak power
• Power up with fan (optional)
• Parallel operation/master-slave operation/N+1 redundant(optional)
• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input voltage (AC85 - 264V)
• Optional:remote ON/OFF, alarms
• Current monitor
• DIN rail (35mm) optional

Ordering Information and Options

ADA(1)  600(2)  F(3)  -  24(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
  G: Low leakage current
  E: Low leakage current
     and EMI class A
  F: with Fan unit
  T: Vertical terminal block
  J: Connector type
  C: with Coating
  R: Remote ON/OFF
  N1: DIN rail
  W: Alarms and Redundant
     operation
Specification is changed at option, refer to Instruction Manual.

Optional Parts

Attachment Plate、Harness、Fan unit

Recommended EMI Filters

Specification

Contents Specifications
Input Voltage AC85 - 264V 1Φ or DC120 - 350V (AC64 or DC90 optionally available) *
Output Wattage 312W (Peak: 600W) ACIN 100V Convection Cooling
504W (Peak: 600W) ACIN 100V Forced Air Cooling
336W (Peak: 744W) ACIN 200V Convection Cooling
600W (Peak: 744W) ACIN 200V Forced Air Cooling
Voltage/Current 48V 6.5A (Peak :12.5A) ACIN 100V Convection Cooling
48V 10.5A (Peak :12.5A) ACIN 100V Forced Air Cooling
48V 7A (Peak :15.5A) ACIN 200V Convection Cooling
48V 12.5A (Peak :15.5A) ACIN 200V Forced Air Cooling
Adjustable  Voltage Range 41.0 - 52.8V
Protection Circuit And Others Overcurrent Protection Works over 101% of peak current and recovers automatically
Overvoltage Protection 64 - 76V
Remote ON/OFF Requirement for external source (Option: -R, refer to Instruction Manual 5)
Remote Sensing -
Others -
Operating Temperature/Humidity -10 to +71℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL (CSA60950-1) , EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
Conducted Noise Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
High Attenuation Complies with IEC61000-3-2 *
Others Dimensions (WxHxD) 65x127x195mm [2.56x5x7.68 inches] (without terminal block)
Weight 1.5kg max
Cooling Method Convection/Forced air
Warranty Period 5-year (Refer to Instruction Manuals)
  • * For further information, please click on the above links.

Block Diagram

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Similar Products

Type Product Name Released Catalog
Instruction Manuals
Enclosed type PBA600F-48 2003
  • Catalog
  • Instruction Manuals
    • * For further information, please click on the above links.