AEA600F-48

Released 2021
RoHS ECO MODEL
UL・C-UL DEMKO CE
Warranty Period 5-year (Refer to Instruction Manuals)

Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

Features of AEA600F-48

•Single output with triple peak current
•High efficiency
•Low profile (41mm, 1.61inch = meet 1U height)
•Medical Isolation Grade 2MOPP (Suitable for BF application)
•Meets EN62477-1 OVCⅢ
•Complies with SEMI F47
•Meets UL508 (Option: -T5)

Ordering Information and Options

AE(1) A(2) 600(3) F(4) - (5) - (6) 

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating
  N: with Cover
  T: Vertical terminal block
  J: Connector type
  R3: with Subfeatures (5V AUX, 12V AUX, Remote, Alarm function)
  T5:UL508
  P5:Overcurrent protection to shut down the output.
Specification is changed at option, refer to Instruction Manual.

Recommended EMI Filters

Specification

Contents Specifications
Input Voltage 85 ~ 264VAC 1Φ
Output Wattage 422.4W (Peak: 1262W) ACIN 230V Convection Cooling
600W (Peak: 1262W) ACIN 230V Forced Air Cooling
Voltage/Current 48V 8.8A (Peak :26.3A) ACIN 230V Convection Cooling
48V 12.5A (Peak :26.3A) ACIN 230V Forced Air Cooling
Adjustable  Voltage Range 43.2 ~ 52.8V
Protection Circuit And Others Overcurrent Protection Works over 101% of rated peak current and recovers automatically
Overvoltage Protection 60.0 ~ 69.6V
Remote ON/OFF -
Remote Sensing -
Others -
Operating Temperature/Humidity -20 to +70℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
Safety And Noise Regulations Agency Approvals (At only AC input) UL62368-1, ANSI/AAMI ES 60601-1, C-UL (eauivalent to CAN/CSA-C22.2 No.62368-1, CAN/CSA-C22.2 No.60601-1) , EN62368-1, EN60601-1 3rd, EN62477-1 (OVCⅢ)
Conducted Noise Complies with FCC Part15 class B, VCCI-B, CISPR11-B, CISPR32-B, EN55011-B, EN55032-B
High Attenuation Complies with EN61000-3-2 class A
Others Dimensions (WxHxD) 41x127x186mm [1.61x5x7.32 inches] (without terminal block)
Weight 1.0kg max
Cooling Method Convection/Forced air
Warranty Period 5-year (Refer to Instruction Manuals)
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Optional Parts

Harness

Category Part Number Description PDF DXF
Harness
H-PA-17 Harness for parallel operation. -