LFP300F-30-TY

Released 2012
RoHS ECO MODEL
UL・C-UL TUV CE UKCA
Warranty Period 5-year (Refer to Instruction Manuals)

This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.

Recommended Model for Replacement

Type Product Name Released Catalog
Instruction Manuals
Documents for replacement
Open Frame type LHP300F-30-Y 2021
  • Catalog
  • Instruction Manuals
    • * For further information and how to use, please see in Cosel product catalog.

    Features of LFP300F-30-TY

    • High power & peak power
    • Small and compact PCB construction
    • Built-in inrush current, overcurrent and overvoltage protection
    circuits
    • Harmonic attenuator (Complies with IEC61000-3-2 class A)
    • Universal input (AC85 - 264V)
    • Power factor correction

    Ordering Information and Options

    LF(1)  P(2)  300(3)  F(4)  -  (5)  -  (6)  

    (1) Series name
    (2) Single output
    (3) Output wattage
    (4) Universal input
    (5) Output voltage
    (6) Optional
      C: with Coating
      G: Low leakage current
      J: EP(Tyco Electronics)Connector type
      J1: VH (J.S.T.) conneclor type
      R: with Remote ON/OFF
      R2: with Remote ON/OFF
      S: with Chassis
      SN: with Chassis & cover
      SNF: with chassis & cover & fan (only 24V)
      T1: Holizontal terminal block
      U1: Can be attached the external
        capacitor unit

    Please refer to Instruction manual 6.

    Recommended EMI Filters

    Specification

    Contents Specifications
    Input Voltage AC85 - 264V 1Φ *
    Output Wattage 300W (Peak: 600W) Convection Cooling
    360W (Peak: 600W) Forced Air Cooling
    Voltage/Current 30V 10A (Peak :20A) Convection Cooling
    30V 12A (Peak :20A) Forced Air Cooling
    Adjustable  Voltage Range 27.00 - 33.00V
    Protection Circuit And Others Overcurrent Protection Works over 101% of rating and recovers automatically
    Overvoltage Protection 34.50 to 42.00V
    Remote ON/OFF Option (Refer to Instruction Manual 6)
    Remote Sensing Not provided
    Others -
    Operating Temperature/Humidity -10 to +70℃, 20 - 90%RH (Non condensing) *
    Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN
    Conducted Noise Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
    High Attenuation Complies with IEC61000-3-2 (class A) *
    Others Dimensions (WxHxD) 95x52.5x222mm [3.74x2.07x8.74 inches] (without terminal block)
    Weight 810g max (with chassis & cover: 1,270g max)
    Cooling Method Convection/Forced air *
    Warranty Period 5-year (Refer to Instruction Manuals)
    • * For further information and how to use, please see in Cosel product catalog.

    Block Diagram

    Documents Download

    Technical Data
    CAD Data DXF
    3D CAD Data STEP
    IGES
    • * For another documents aren't listed, please feel free to contact to a Cosel representative.

    Optional Parts

    Harness、External capacitor unit

    Category Part Number Description PDF DXF
    Harness
    H-IN-13 Mating harness for input of the connector type power supply. (Mfr : Tyco Electronics) -
    H-IN-14 Mating harness for input of the connector type power supply. (Mfr : J.S.T.) -
    H-IN-23 Mating harness for connecting the external capacitor unit. -
    H-OU-11 Mating harness for output of the connector type power supply. (Mfr : J.S.T.) -
    H-OU-12 Mating harness for output of the connector type power supply. (Mfr : J.S.T.) -
    H-OU-31 Mating harness for output of the connector type power supply. (Mfr : Tyco Electronics) -
    H-OU-32 Mating harness for output of the connector type power supply. (Mfr : Tyco Electronics) -
    H-RC-1 Harness for using option : -R. -
    External Capacitor unit
    CR-HUT241-1 External capacitor unit to extend Hold-up time.
    (Capacitance : 240uF)
    -
    CR-HUT721-1 External capacitor unit to extend Hold-up time.
    (Capacitance : 720uF)
    -
    CR-HUT282-2 External capacitor unit to extend Hold-up time.
    (Capacitance : 2,800uF)
    -
    CR-HUT502-2 External capacitor unit to extend Hold-up time.
    (Capacitance : 5,040uF)
    -
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.