Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Recommended Model for Replacement
Type | Product Name | Released | Catalog Instruction Manuals Documents for replacement |
|
---|---|---|---|---|
Enclosed type | AEA800F-36 | 2022 |
|
- * For further information and how to use, please see in Cosel product catalog.
Features of ADA750F-36
• High power & peak power• Power up with fan (optional)
• Parallel operation/master-slave operation/N+1 redundant(optional)
• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input voltage (AC85 - 264V)
• Optional:remote ON/OFF, alarms
• Current monitor
• DIN rail (35mm) optional
Ordering Information and Options
ADA(1) 750(2) F(3) - 24(4) - □(5)
(1) Series name(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
G: Low leakage current
E: Low leakage current
and EMI class A
F: with Fan unit
T: Vertical terminal block
J: Connector type
C: with Coating
R: Remote ON/OFF
N1: DIN rail
W: Alarms and Redundant
operation
Specification is changed at option, refer to Instruction Manual.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ or DC120 - 350V (AC64 or DC90 optionally available) * | |
Output | Wattage |
396W (Peak: 1008W) ACIN 100V Convection Cooling 594W (Peak: 1008W) ACIN 100V Forced Air Cooling 450W (Peak: 1512W) ACIN 200V Convection Cooling 738W (Peak: 1512W) ACIN 200V Forced Air Cooling |
Voltage/Current |
36V 11A (Peak :28A) ACIN 100V Convection Cooling 36V 16.5A (Peak :28A) ACIN 100V Forced Air Cooling 36V 12.5A (Peak :42A) ACIN 200V Convection Cooling 36V 20.5A (Peak :42A) ACIN 200V Forced Air Cooling |
|
Adjustable Voltage Range | 33.0 - 41.0V | |
Protection Circuit And Others | Overcurrent Protection | Works over 101% of peak current and recovers automatically |
Overvoltage Protection | 51 - 60V | |
Remote ON/OFF | Requirement for external source (Option: -R, refer to Instruction Manual 5) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +71℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN and IEC60950-1 |
Conducted Noise | Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B | |
High Attenuation | Complies with IEC61000-3-2 * | |
Others | Dimensions (WxHxD) | 70x127x230mm [2.76x5x9.06 inches] (without terminal block) |
Weight | 1.9kg max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Attachment Plate、Harness、Fan unit
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Attachment |
F-ADA-1 | Attachment to facilitate installation for A and B mounting with ADA series. | ||
F-ADA-2 | Attachment to facilitate installation for A and B mounting with ADA series. | |||
F-ADA-3 | Attachment to facilitate installation for A mounting with ADA series. | |||
F-ADA-4 | Attachment to facilitate installation for C mounting with ADA series. | |||
Harness |
H-IN-11 | Mating harness for input of the connector type power supply. (J option) | - | |
H-OU-26 | Mating harness for output with J option. | - | ||
H-PA-5 | Harness for parallel operation when I/O interface is connector type. (option : J) | - | ||
H-RC-2 | Harness for using option : -R when I/O interface is connector type (option : J) | - | ||
H-SN-23 | Harness for using option : -W and/or -R when I/O interface is terminal block type (standard). | - | ||
Fan unit |
FAN-AD7-24 | Fan unit for ADA750F-24. | - | |
FAN-AD7-48 | Fan unit for ADA750F-30/36/48. | - |