MAX1600F

Discontinued (May, 2020)

Released 2000
Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 1600W
Slots: 4
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,28V
 
RoHS
UL・C-UL TUV CE
Warranty Period 3-year

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

Recommended Model for Replacement

Type Model Name Released Catalog
Instruction Manuals
Documents for replacement
Configurable type ACE900F 2001
  • Catalog
  • Instruction Manuals
  • Enclosed type PBA600F 2003
  • Catalog
  • Instruction Manuals
  • Enclosed type PBA1000F 2004
  • Catalog
  • Instruction Manuals
  • Enclosed type PBA1500F 2003
  • Catalog
  • Instruction Manuals
  • Enclosed type PCA600F 2018
  • Catalog
  • Instruction Manuals
    • * For further information and how to use, please see in Cosel product catalog.
    • * Please use them together with the mentioned product to get required outputs.

    Features of MAX1600F

    • Flexible modular system architecture provides various output configurations
    • Harmonic attenuator (Complies with IEC61000-3-2) : MAX1600F
    • Universal input voltage
    • High power factor
    • Various functions
    • Remote ON/OFF control, alarm, parallel operation

    Ordering Information and Options

    M1(1)  -  (6)  (7)  (8)  (9)  -  (10)  -  (11)  

    (1) Abbreviation type name of MAX series
     M1F: MAX1600F
    (2) Slot 8 Output module
    (3) Slot 7 Output module
    (4) Slot 6 Output module
    (5) Slot 5 Output module
    (6) Slot 4 Output module
    (7) Slot 3 Output module
    (8) Slot 2 Output module
    (9) Slot 1 Output module
    (10) Parallel code
    (11) Series and option code
       Refer to instruction manual

    * The number of slot is different depending on the model.

    Recommended EMI Filters

    Specification

    Input Module

    Contents Specifications
    Input Voltage AC85 - 264V 1Φ / DC120 - 350V
    Output Number of Slot 4
    Total Output power AC90 - 150V 1500W
    AC170 - 264V 1600W
    Operating Temperature/Humidity -20 to +65℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
    Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL (CSA60950-1) , EN60950-1, EN50178, Complies with DEN-AN (At only AC input)
    Conducted Noise Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B
    High Attenuation Complies with IEC61000-3-2 *
    Others Dimensions (WxHxD) 200x97x300mm [7.87x3.82x11.81 inches]
    Weight 7kg max
    Cooling Method Forced cooling (built-in)
    Warranty Period 3-year
    • * For further information and how to use, please see in Cosel product catalog.

    Output Module

    Contents
    Specifications
    Module Code
    Number of Slots Used
    Output Wattage
    Voltage/Current
    Adjustable  Voltage Range
    Protection Circuit And Others Overcurrent
    Protection
    Overvoltage
    Protection
    Remote
    ON/OFF
    Remote
    Sensing
    Others
    A B C D E F G H I
    1 1 1 1 1 1 1 1 1
    160W 264W 400W 405W 408W 405W 396W 408W 406W
    2V 80A 3.3V 80A 5V 80A 7.5V 54A 12V 34A 15V 27A 18V 22A 24V 17A 28V 14.5A
    1.98 - 2.20V 2.64 - 3.63V 4.00 - 5.50V 6.00 - 8.25V 9.60 - 13.2V 12.0 - 16.5V 14.4 - 19.8V 19.2 - 26.4V 22.4 - 30.8V
    Works over 105%min of rated current. Automatic recovery.
    4.00 - 5.50V 4.00 - 5.50V 5.75 - 7.00V 8.63 - 10.5V 13.8 - 16.8V 17.25 - 21.0V 20.7 - 25.2V 27.6 - 33.6V 32.2 - 39.2V
    Available
    Available
    -
     
    • * For further information and how to use, please see in Cosel product catalog.

    Block Diagram

    Documents Download

    Here is a technical data.
    Please click here to download.

    Download

    Technical Data
    CAD Data
    • * For another documents aren't listed, please feel free to contact to a Cosel representative.
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.