Rated Input: AC85 - 264V 1Φ
Rated Output Wattage: 900W
Slots: 6
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,34V,48V,±5,±12,±15,±24,5V/5V,5V/12V,5V/24V
Rated Output Wattage: 900W
Slots: 6
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,34V,48V,±5,±12,±15,±24,5V/5V,5V/12V,5V/24V
Warranty Period | 3-year |
---|
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Recommended Model for Replacement
Type | Model Name | Released | Catalog Instruction Manuals Documents for replacement |
|
---|---|---|---|---|
Configurable type | AME1200F | 2019 |
|
- * For further information and how to use, please see in Cosel product catalog.
Features of ACE900F
• Flexible modular system architecture provides various output configuration• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input (AC85-264V)
• Remote ON/OFF control, alarm
Ordering Information and Options
AC(1) □(2) - □(3) □(4) □(5) □(6) □(7) □(8) - □□(9) - □□(10)
(1) Abbreviation type name of ACE series(2) Abbreviation power of ACE series
9: ACE900F(AC9)
(3) Slot 6 Output module
(4) Slot 5 Output module
(5) Slot 4 Output module
(6) Slot 3 Output module
(7) Slot 2 Output module
(8) Slot 1 Output module
(9) Parallel code
(10) Option (series code)
Refer to instruction manual 5.1
Safety: UL60601-1, EN60601-1
Refer to instruction manual.
*The number of slot is different depending on the model.
*Empty slot is code: 0
Recommended EMI Filters
Specification
Input Module
Contents | Specifications | ||
---|---|---|---|
Input Voltage | AC85 - 264V 1Φ / DC120 - 350V * | ||
Output | Number of Slot | 6 | |
Total Output power | AC90 - 150V | 800W (Peak 1kW) | |
AC170 - 264V | 900W (Peak 1kW) | ||
Operating Temperature/Humidity | -20 to +70℃, 20 - 90%RH (Non condensing) | ||
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN UL60601-1, EN60601-1 (H option) |
|
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR22-B and EN55022-B | ||
High Attenuation | Complies with IEC61000-3-2 * | ||
Others | Dimensions (WxHxD) | 177.5x63.5x254mm [6.99x2.5x10 inches] | |
Weight | 3.0kg max | ||
Cooling Method | Forced cooling (built-in) | ||
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Output Module
50W Suitable Single Output
Contents | Specifications | |||||
---|---|---|---|---|---|---|
Module Code | L | M | N | P | R | |
Number of Slots Used | 1 | 1 | 1 | 1 | 1 | |
Output | Wattage | 33W | 50W | 60W | 60W | 60W |
Voltage/Current | 3.3V 10A | 5V 10A | 12V 5A | 15V 4A | 24V 2.5A | |
Adjustable Voltage Range | 2.60 - 3.60V | 4.00 - 5.50V | 9.00 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
Protection Circuit And Others |
Overcurrent Protection | Works over 105%min of rated current. Automatic recovery. |
||||
Overvoltage Protection | 4.00 - 5.25V | Works at 115 - 140% of rated voltage | ||||
Remote ON/OFF | Available |
|||||
Remote Sensing | - |
|||||
Others | - |
150W Suitable Single Output
Contents
Specifications
Module Code | |
---|---|
Number of Slots Used | |
Output | Wattage |
Voltage/Current | |
Adjustable Voltage Range | |
Protection Circuit And Others |
Overcurrent Protection |
Overvoltage Protection |
|
Remote ON/OFF |
|
Remote Sensing |
|
Others |
A | B | C | D | E | F | G | H | J | K |
1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
52W | 85.8W | 130W | 135W | 156W (Peak 168W) |
150W (Peak 180W) |
153W (Peak 180W) |
156W (Peak 192W) |
153W (Peak 187W) |
153.6W (Peak 192W) |
2V 26A | 3.3V 26A | 5V 26A | 7.5V 18A | 12V 13A (Peak 14A) |
15V 10A (Peak 12A) |
18V 8.5A (Peak 10A) |
24V 6.5A (Peak 8A) |
34V 4.5A (Peak 5.5A) |
48V 3.2A (Peak 4A) |
1.60 - 2.60V | 2.60 - 3.60V | 4.00 - 5.50V | 6.00 - 8.20V | 9.00 - 13.2V | 13.2 - 16.5V | 16.5 - 19.2V | 19.2 - 26.4V | 27.2 - 37.4V | 38.4 - 52.8V |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery. |
|||||||||
3.00 - 4.80V | 4.00 - 5.25V | Works at 115 - 140% of rated voltage | |||||||
Available |
|||||||||
Available |
|||||||||
- |
300W Suitable Single Output
Contents
Specifications
Module Code | |
---|---|
Number of Slots Used | |
Output | Wattage |
Voltage/Current | |
Adjustable Voltage Range | |
Protection Circuit And Others |
Overcurrent Protection |
Overvoltage Protection |
|
Remote ON/OFF |
|
Remote Sensing |
|
Others |
2A | 2B | 2C | 2D | 2E | 2F | 2G | 2H | 2J | 2K |
2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
120W | 198W | 300W | 300W | 300W (Peak 408W) |
300W (Peak 405W) |
306W (Peak 414W) |
336W (Peak 480W) |
340W (Peak 476W) |
336W (Peak 480W) |
2V 60A | 3.3V 60A | 5V 60A | 7.5V 40A | 12V 25A (Peak 34A) |
15V 20A (Peak 27A) |
18V 17A (Peak 23A) |
24V 14A (Peak 20A) |
34V 10A (Peak 14A) |
48V 7A (Peak 10A) |
1.60 - 2.60V | 2.60 - 3.60V | 4.00 - 5.50V | 6.00 - 8.20V | 9.00 - 13.2V | 13.2 - 16.5V | 16.5 - 19.2V | 19.2 - 26.4V | 27.2 - 37.4V | 38.4 - 52.8V |
Works over 105%min of rated current or 101%min of peak current. Automatic recovery. |
|||||||||
3.00 - 4.80V | 4.00 - 5.25V | Works at 115 - 140% of rated voltage | |||||||
Available |
|||||||||
Available |
|||||||||
- |
75W Dual Output
Contents | Specifications | ||||
---|---|---|---|---|---|
Module Code | Y | W | Z | 9 | |
Number of Slots Used | 1 | 1 | 1 | 1 | |
Output | Wattage* | 50W | 76.8W | 75W | 76.8W |
Voltage | ±5V | ±12V | ±15V | ±24V | |
Current1* | 3A | 3.2A | 2.5A | 1.6A | |
Current2* | 7A | 4.2A | 3.5A | 2.5A | |
Peak Current* | - | 5A | 4A | - | |
Adjustable Voltage Range | 4.99 - 6.00V | 9.60 - 13.2V | 13.2 - 16.5V | 19.2 - 26.4V | |
Protection Circuit And Others |
Overcurrent Protection | Works over 105%min of rated current or 101%min of peak current. Automatic recovery. |
|||
Overvoltage Protection | 6.90 - 8.40V | 13.8 - 16.8V | 17.25 - 21.0V | 27.6 - 33.6V | |
Remote ON/OFF | Available |
||||
Remote Sensing | - |
||||
Others | - |
150W Dual Output
Contents | Specifications | ||
---|---|---|---|
Module Code | Q | V | |
Number of Slots Used | 1 | 1 | |
Output | Wattage* | 153.6W | 165W |
Voltage | ±12V | ±15V | |
Current1* | 6.4A | 5.5A | |
Current2* | 8A | 7A | |
Peak Current* | 10A | 8A | |
Adjustable Voltage Range | 9.60 - 13.2V | 13.2 - 16.5V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105%min of rated current or 101%min of peak current. Automatic recovery. |
|
Overvoltage Protection | Works at 115 - 140% of rated voltage | ||
Remote ON/OFF | Available |
||
Remote Sensing | - |
||
Others | - |
100W Insulation Dual Output
Contents | Specifications | ||||||
---|---|---|---|---|---|---|---|
Module Code | S | T | U | ||||
Number of Slots Used | 1 | 1 | 1 | ||||
Output | Wattage | 75W | 100.4W | 100.4W | |||
Voltage/Current | V1: 5V 10A |
V2: 5V 5A |
V1: 5V 10A |
V2: 12V 4.2A |
V1: 5V 10A |
V2: 24V 2.1A |
|
Adjustable Voltage Range | 4.99 - 5.50V | 3.00 - 5.50V | 4.99 - 5.50V | 7.50 - 13.2V | 4.99 - 5.50V | 15.0 - 26.4V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105%min of rated current. Automatic recovery. |
|||||
Overvoltage Protection | Works at 115 - 140% of rated voltage |
||||||
Remote ON/OFF | Available |
||||||
Remote Sensing | - |
||||||
Others | - |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Here is a technical data.
Please click here to download.
Technical Data |
|
---|---|
CAD Data |
|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness,Fan unit
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-SN-14 | Harness for using AUX and PR alarm of CN1. | - | |
H-SN-16 | Harness for using all functions of output modules. (CN2) | - | ||
H-SN-17 | Harness for using all functions except remote sensing of output modules. (CN2) | - | ||
H-SN-18 | Harness for using remote ON/OFF of output modules S,T,U. (CN2) | - | ||
Fan unit |
FAN-AC9 | Fan unit for ACE900F. (Standard model) |
- | |
FAN-AC9-F | Fan unit for ACE900F. (F option : reversed air flow) |
- | ||
FAN-AC9-K | Fan unit for ACE900F. (K option : Lower speed fan) |
- | ||
FAN-AC9-T | Fan unit for ACE900F. (T option : With filter) |
- | ||
Terminal Attachment |
B-ACE-7 | Terminal attachment to facilitate faston terminal output modules. | - | |
B-ACE-8 | Terminal attachment to facilitate wiring. | - | ||
B-ACE-9 | Terminal attachment for series operation as output modules. | - |