Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of AEA800F-30
• Single output with triple peak current• High efficiency
• Low profile (50mm)
• Medical Isolation Grade 2MOPP (Suitable for BF application)
• Meets EN62477-1 OVCⅢ
• Complies with SEMI F47
Ordering Information and Options
AE(1) A(2) 800(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
N: with Cover
T: Vertical terminal block
J: Connector type
R3: with Subfeatures (5V AUX, 12V AUX, Remote, Alarm function)
I4: with MODBUS interface and Subfeatures (5V AUX, 12V AUX, Remote, Alarm function)
T5: UL508 (Except 30V)
P5: Overcurrent protection to shut down the output.
Specification is changed at option, refer to Instruction Manual.
3D product images are available.
Read Me First
Standard N: with Cover T: Vertical terminal block J: Connector type
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | 85 - 264VAC 1Φ * | |
Output | Wattage |
564.0W (Peak: 1740W) 230VAC, Convection Cooling 816.0W (Peak: 1740W) 230VAC, Forced Air Cooling |
Voltage/Current |
30V, 18.8A (Peak: 58.0A) 230VAC, Convection Cooling 30V, 27.2A (Peak: 58.0A) 230VAC, Forced Air Cooling |
|
Adjustable Voltage Range | 27.0 - 33.0V | |
Protection Circuit And Others | Overcurrent Protection | Works over 101% of rated peak current and recovers automatically |
Overvoltage Protection | 37.5 - 42.0V | |
Remote ON/OFF |
Optional (Option -R3. -I4. Refer to Instruction Manuals) |
|
Remote Sensing | - | |
Others | Series and parallel operation * | |
Operating Temperature/Humidity |
-20 to +70℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) |
|
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, ANSI/AAMI ES 60601-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1, CAN/CSA-C22.2 No.60601-1) , EN62368-1, EN60601-1 3rd, EN62477-1 (OVCⅢ) |
Conducted Noise | Complies with FCC Part15 class B, VCCI-B, CISPR11-B, CISPR32-B, EN55011-B, EN55032-B | |
High Attenuation | Complies with EN61000-3-2 class A | |
Others | Dimensions (WxHxD) |
50x127x203.2mm [1.97x5x8 inches] (without terminal block) |
Weight | 1.3kg max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-IN-11 | Mating harness for input of the connector type power supply. (J option) | - | |
H-OU-53 | Mating harness for output with J option. | - | ||
H-PA-17 | Harness for parallel operation. | - | ||
H-SN-39 | Harness for using functions of CN4 (option: -I4) . | - | ||
H-SN-71 | Harness for using functions of CN3 (option:-R3 and -I4) . | - |