JAC-30

Released 2014
Three-phase 500VAC 30A
Compact and low profile
High-attenuation from 150kHz to 1MHz
1-stage filter
 
RoHS ECO MODEL
UL・C-UL VDE ENEC
Warranty Period 5-year

The terminal cover is retracted inside the unit.
DIN rail installation type is option.

Features of JAC-30

Maximum input voltage 528VAC: 10% fluctuations in voltage 480VAC
Selectable leakage current value

Push down type terminal block

Ordering Information and Options

JAC(1)  -  30(2)  -  683(3)  -  (4)  

(1) Model Name
(2) Rated Current
(3) Line to ground capacitor code
  Refer to Product Line-up.
  * When the line to ground capacitor code is different, the attenuation characteristic is
    different.
(4) Options
  D:DIN rail installation type
    * The dimensions change when the option is set. Refer to External view.
  H:Ultra high-attenuation type
    "103" , "223" , "683" is applied.
  U:lmprove differential mode attenuation (Rated voltage 250V)

Product Line-up

Product Name Leakage Current* Line to ground capacitor
(nominal value)
JAC-30-103 0.5mA / 1.0mA max 10,000pF
JAC-30-223 1.0mA / 2.0mA max 22,000pF
JAC-30-683 2.5mA / 5.0mA max 68,000pF
JAC-30-224 15mA / 24mA max 220,000pF
  • * Input 250/500VAC 60Hz ( input 250/400VAC 60Hz in case of 224)

Specification

Contents Specifications
Rated Voltage Three-phase Three-wire 500V 50/60Hz
Rated Current 30A
Operating Temperature -40 to +85℃ (Refer to Derating Curve)
Agency Approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
Others Dimensions (WxHxD) 63x44x132 mm [2.48x1.73x5.20 inches] (Option: -D refer to external view)
Weight 440g max
Warranty Period 5-year
  • * For further information and how to use, please see in Cosel product catalog.

Circuit Diagram

Derating Curve

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Similar Model (Rated Voltage and Current)

Features Model Name Released Catalog
Instruction Manuals
General purpose,
Low profile,
High-attenuation type,
1-stage filter
TAC-30 2005 Catalog
Instruction Manuals
Low profile,
Ultra high-attenuation type,
1-stage filter
TAH-30 2006 Catalog
Instruction Manuals
Book type,
EMI/EMC Filter for motor drive system,
2-stage filter
FSB-30 2016 Catalog
Instruction Manuals
  • * For further information and how to use, please see in Cosel product catalog.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.