FTA-125

Released 2015

Features of FTA-125

Space-saving type
Maximum input voltage 528VAC: 10% fluctuations in voltage 480VAC
Selectable leakage current value

Ordering Information and Options

FTA(1)  -  125(2)  -  683(3)  -  (4)  

(1) Model Name
(2) Rated Current
(3) Line to ground capacitor code
  Refer to Product Line-up.
  * When the line to ground capacitor code is different, the attenuation characteristic is
    different.
(4) Option
  H:Ultra high attenuation type
    155, 335 is not applied.
  S:Hexagon socket head cap screw (Standard type is Hexagon head screw)
  U:lmprove differential mode attenuation (Rated voltage 250V)
  G:With switch of line to ground capacitor
    Only 155, 335 is applied.
     * Leakage current
      155 : Switch state is ON (switched to “|”) 160mA/250mA max
               Switch state is OFF (switched to “○”) 50μA/80μA max
      335 : Switch state is ON (switched to “|”) 320mA/500mA max
               Switch state is OFF (switched to “○”) 50μA/80μA max

Product Line-up

Product Name Leakage Current* Line to ground capacitor
(nominal value)
FTA-125-223 1.0mA/2.0mA max 22,000pF
FTA-125-683 2.5mA/5.0mA max 68,000pF
FTA-125-104 3.5mA/7.0mA max 100,000pF
FTA-125-155 160mA/250mA max 1.5μF
FTA-125-335 320mA/500mA max 3.3μF
  • * Input 250/500VAC 60Hz ( input 250/400VAC 60Hz in case of 155 and 335)

Specification

Contents Specifications
Rated Voltage Three-phase Three-wire 500V 50/60Hz
Rated Current 125A
Operating Temperature -40 to +85℃ (Refer to Derating Curve)
Agency Approvals UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC
Others Dimensions (WxHxD) 100x130x210 mm [3.94x5.12x8.27 inches]
(Option: -G refer to external view)
Weight 3.1kg max
Warranty Period 5-year
  • * For further information and how to use, please see in Cosel product catalog.

Circuit Diagram

Derating Curve

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Similar Model (Rated Voltage and Current)

Features Model Name Released Catalog
Instruction Manuals
General purpose,
Low profile,
High-attenuation type,
1-stage filter
TAC-150 2008 Catalog
Instruction Manuals
Low-profile,
High-attenuation,
2-stage filter
TBC-150 2008 Catalog
Instruction Manuals
Book type,
High-attenuation,
2-stage filter
FTB-150 2011 Catalog
Instruction Manuals
Book type,
EMI/EMC Filter for motor drive system,
2-stage filter
FSB-150 2017 Catalog
Instruction Manuals
  • * For further information and how to use, please see in Cosel product catalog.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.