PLA600F-5

Discontinued (June, 2017)

Released 2011
RoHS ECO MODEL
UL・C-UL TUV CE UKCA
Warranty Period 5-year (Refer to Instruction Manuals)

*New model available, PJA600F
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

Recommended Model for Replacement

Type Product Name Released Catalog
Instruction Manuals
Documents for replacement
Enclosed type PJA600F-5 2017
  • Catalog
  • Instruction Manuals
    • * For further information and how to use, please see in Cosel product catalog.

    Features of PLA600F-5

    • Cost-effective
    • Longer life (see Instruction Manual)
    • Low profile (meets 2U height = 61 mm or 2.40 inches)
    • Wide operating temperature range (-20 to +70 see instruction manual)
    • Screw hold type terminal block
    • Slow fan speed at no load
    • Many optional functions
    • Complies with SEMI F-47 (-U option, see Instruction Manual for details)

    Ordering Information and Options

    PL(1)  A(2)  600(3)  F(4)  -  (5)  -  (6)  

    (1) Series name
    (2) Single output
    (3) Output wattage
    (4) Universal input
    (5) Output voltage
    (6) Optional
       C: with Coating
       G: Low leakage current
       V: External potentiometer for output voltage adjustment
       U: Low input voltage stop (Complies with SEMI F-47)
       W: Parallel operation, LV alarm Remote sensing
       R: with Remote ON/OFF (Required external power source)
       F4: Low speed fan
       T2: Horizontal terminal block (non-screw-hold type)

    See 5.1 in Instruction Manual.

    Recommended EMI Filters

    Specification

    Contents Specifications
    Input Voltage AC85 - 264V 1Φ *
    Output Wattage 500W ACIN 115V - 264V
    Voltage/Current 5V 100A
    Adjustable  Voltage Range 4.50 - 5.50V
    Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically
    Overvoltage Protection 5.75 to 7.00V
    Remote ON/OFF Optional (Required external power source. Option -R)
    Remote Sensing Optional (Option -W)
    Others -
    Operating Temperature/Humidity -20 to +70℃ (Output derating is required) , 20 - 90%RH (Non condensing)
    Safety And Noise Regulations Agency Approvals (At only AC input) UL62368-1, C-UL (CSA62368-1) , EN62368-1
    Complies with DEN-AN
    Conducted Noise Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
    High Attenuation Complies with IEC61000-3-2 class A
    Others Dimensions (WxHxD) 120x61x215mm [4.72x2.40x8.46 inches] (Excluding terminal block and screw)
    Weight 2.0kg max
    Cooling Method Forced cooling (internal fan)
    Warranty Period 5-year (Refer to Instruction Manuals)
    • * For further information and how to use, please see in Cosel product catalog.

    Block Diagram

    Documents Download

    Technical Data
    CAD Data DXF
    3D CAD Data STEP
    IGES
    • * For another documents aren't listed, please feel free to contact to a Cosel representative.

    Similar Products

    Type Product Name Released Catalog
    Instruction Manuals
    Enclosed type PBA600F-5 2003
  • Catalog
  • Instruction Manuals
  • Enclosed type PJA600F-5 2017
  • Catalog
  • Instruction Manuals
    • * For further information and how to use, please see in Cosel product catalog.
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.