Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
*New model available, PJA600F
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Recommended Model for Replacement
Type | Product Name | Released | Catalog Instruction Manuals Documents for replacement |
|
---|---|---|---|---|
Enclosed type | PJA600F-12 | 2017 |
|
- * For further information and how to use, please see in Cosel product catalog.
Features of PLA600F-12
• Cost-effective• Longer life (see Instruction Manual)
• Low profile (meets 2U height = 61 mm or 2.40 inches)
• Wide operating temperature range (-20 to +70 see instruction manual)
• Screw hold type terminal block
• Slow fan speed at no load
• Many optional functions
• Complies with SEMI F-47 (-U option, see Instruction Manual for details)
Ordering Information and Options
PL(1) A(2) 600(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
V: External potentiometer for output voltage adjustment
U: Low input voltage stop (Complies with SEMI F-47)
W: Parallel operation, LV alarm Remote sensing
R: with Remote ON/OFF (Required external power source)
F4: Low speed fan
T2: Horizontal terminal block (non-screw-hold type)
See 5.1 in Instruction Manual.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ * | |
Output | Wattage | 600W ACIN 115V - 264V |
Voltage/Current | 12V 50A | |
Adjustable Voltage Range | 10.80 - 13.20V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | 13.80 to 16.80V | |
Remote ON/OFF | Optional (Required external power source. Option -R) | |
Remote Sensing | Optional (Option -W) | |
Others | - | |
Operating Temperature/Humidity | -20 to +70℃ (Output derating is required) , 20 - 90%RH (Non condensing) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL (CSA62368-1) , EN62368-1 Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B | |
High Attenuation | Complies with IEC61000-3-2 class A | |
Others | Dimensions (WxHxD) | 120x61x215mm [4.72x2.40x8.46 inches] (Excluding terminal block and screw) |
Weight | 2.0kg max | |
Cooling Method | Forced cooling (internal fan) | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Similar Products
Type | Product Name | Released | Catalog Instruction Manuals |
|
---|---|---|---|---|
Enclosed type | PBA600F-12 | 2003 |
|
|
Enclosed type | PJA600F-12 | 2017 |
|
- * For further information and how to use, please see in Cosel product catalog.