Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
*New model available, PJA100F
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Recommended Model for Replacement
Type | Product Name | Released | Catalog Instruction Manuals Documents for replacement |
|
---|---|---|---|---|
Enclosed type | PJA100F-24 | 2016 |
|
- * For further information and how to use, please see in Cosel product catalog.
Features of PLA100F-24
• Compact design (Depth: 109mm 4.29inches)• High efficiency (88%typ PLA100F-24, AC230Vin, 100% load)
• Low power consumption (1.5W typ AC240Vin, no load at standard model)
• UL508 approved (Except option -J) , and complies with SEMI F47 (see instruction manual 1.1)
• Various connection interface options (vertical terminal [-T], AMP connector [-J])
Ordering Information and Options
PL(1) A(2) 100(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
R: with Remote ON/OFF (Required external power source)
J: Connector interface
T: Vertical terminal block
L: Lower power consumption (0.5W max at AC240Vin, no load, ErP-compliant)
N1: with DIN rail
See 5.1 in Instruction Manual.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ * | |
Output | Wattage | 103.2W ACIN 115V - 264V |
Voltage/Current | 24V 4.3A | |
Adjustable Voltage Range | 21.60 - 26.40V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | 27.60 to 33.60V | |
Remote ON/OFF | Optional (Required external power source. Option -R) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -20 to +70℃ (Output derating is required) , 20 - 90%RH (Non condensing) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL (CSA62368-1) , EN62368-1, UL508 (Except option -J) Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B | |
High Attenuation | Complies with IEC61000-3-2 class A | |
Others | Dimensions (WxHxD) | 41x97x109mm [1.61x3.82x4.29 inches] (Excluding terminal block and screw) |
Weight | 500g max | |
Cooling Method | Convection | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Similar Products
Type | Product Name | Released | Catalog Instruction Manuals |
|
---|---|---|---|---|
Enclosed type | PBA100F-24 | 2004 |
|
|
Enclosed type | PJA100F-24 | 2016 |
|
- * For further information and how to use, please see in Cosel product catalog.