PBA300F-7R5

Released 2004
RoHS ECO MODEL
UL・C-UL TUV CE UKCA
Warranty Period 5-year (Refer to Instruction Manuals)

*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.

Features of PBA300F-7R5

• Super small-size & light weight
• Harmonic attenuator (Complies with IEC61000-3-2): except PBA1500T
• Universal input (AC85 - 264V): PBA1500T AC170-264V 3Φ
• Efficiency increased with synchronous rectification technology (PBA50F - 150F)
• Variety of option (PBA10F - 150F, PBW15F - 50F)
• Parallel operation and Parallel redundancy operation (PBA300F - 1500F, PBA1500T)
• Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T)

Ordering Information and Options

PB(1)  A(2)  300(3)  F(4)  -  5(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating
  G: Low leakage current
  U: Operation stop voltage is set at a lower value
  F3: Reverse air exhaust type
  F4: Low speed fan
  N1: with DIN rail

Refer to instruction manual 7.1.

Recommended EMI Filters

Specification

Contents Specifications
Input Voltage AC85 - 264V 1Φ or DC120 - 350V *
Output Wattage 300W
Voltage/Current 7.5V 40A
Adjustable  Voltage Range 5.25 - 8.25V
Protection Circuit And Others Overcurrent Protection Works over 105% of rated current or 101% of peak current and recovers automatically
Overvoltage Protection 9.0 - 11.6V
Remote ON/OFF Provided
Remote Sensing Provided
Others -
Operating Temperature/Humidity -20 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing)
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL (CSA60950-1) , EN62368-1
Complies with DEN-AN
Conducted Noise Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
High Attenuation Complies with IEC61000-3-2 *
Others Dimensions (WxHxD) 102x42x170mm [4.02x1.65x6.69 inches] (without terminal block and screw)
Weight 1.0kg max
Cooling Method Forced cooling (internal fan)
Warranty Period 5-year (Refer to Instruction Manuals)
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Optional Parts

DIN Rail Attachment Plate, Harness, Fan unit

Category Part Number Description PDF DXF
DIN rail Attachment Plate
FD-PBA300 DIN rail attachment plate.
(DIN rail width : 35mm)
Harness
H-PA-3 Harness for parallel operation. -
H-SN-20 Harness for using all functions of CN1 and CN2. -
H-SN-21 Harness for using all functions except remote sensing of CN2. -
H-SN-22 Harness for using all functions of CN3. -
H-SN-24 Harness for using example remote ON/OFF circuit C. -
Fan unit
FAN-PB3 Fan unit for PBA300F.
(Standard model)
-
FAN-PB3-F3 Fan unit for PBA300F.
(F3 option : Reversed air flow)
-
FAN-PB3-F4 Fan unit for PBA300F.
(F4 option : Lower speed fan)
-
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.