Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care.
Features of LHP300F-36-Y
• High power & high peak power• EN62477-1(OVC Ⅲ)
• Small and compact PCB construction
• Low profile
• High Efficiency
• Low Noise
• Harmonic attenuator (Complies with IEC61000-3-2)
• Extensive optional parts such as dedicated harness are available
• Wide operating temperature
• Complies with SEMI F47
• An option "-R2" and "-R5" with reduced standby power is available when the remote control is off.
Ordering Information and Options
LH(1) P(2) 300(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
J4: EP (TE Connectivity) connector type
J5: 8 pin type(Output connector)
R☐: with Remote ON/OFF
S: with Chassis
SN: with Chassis & cover
T: Terminal block style
T4: Push-in Terminal block type
T5: UL508
U1: Can be attached the external capacitor unit
DC: DC input
Please refer to Instruction manual 7.
3D product images are available.
Read Me First
Standard model SN:with chassis & cover T4:Push-inTerminal block type
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | 85 - 264VAC 1Φ * | |
Output | Wattage | 302.4W(604.8W) |
Voltage/Current | 36V 8.4A(Peak:16.8A) | |
Adjustable Voltage Range | 34.20 - 39.60V | |
Protection Circuit And Others | Overcurrent Protection | Works over 101% of peak current rating and recovers automatically |
Overvoltage Protection | 41.4 - 50.4V | |
Remote ON/OFF | Option (Refer to Instruction Manual) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +70℃, 20 - 90%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1) , EN62368-1, EN62477-1(Overvoltage category Ⅲ) ,Complies with DEN-AN* |
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR11-B, CISPR32-B, EN55011-B, EN55032-B | |
High Attenuation | Complies with IEC61000-3-2 (Class A) * | |
Others | Dimensions (WxHxD) | 84x37x180mm [3.31x1.46x7.09 inches] |
Weight | 580g max | |
Cooling Method | Convection/Forced air * | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-IN-5 | Mating harness for input of the connector type power supply. (Mfr : J.S.T.) | - | |
H-IN-10 | Mating harness for input of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-IN-12 | Mating harness for output with J4 option. (Mfr : TE Connectivity) | - | ||
H-IN-25 | Mating harness for connecting the external capacitor unit. | - | ||
H-OU-10 | Mating harness for output with J5 option. (Mfr : J.S.T.) | - | ||
H-OU-46 | Mating harness for output of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-OU-47 | Mating harness for output with J4 option. (Mfr : TE Connectivity) | - | ||
H-OU-54 | Mating harness for output with J5 option. (Mfr : J.S.T.) | - | ||
H-RC-1 | Harness for using option : -R. | - | ||
External Capacitor unit |
CR-HUT241-1 | External capacitor unit to extend Hold-up time. (Capacitance : 240uF) |
- | |
CR-HUT721-1 | External capacitor unit to extend Hold-up time. (Capacitance : 2,800uF) |
- | ||
CR-HUT282-2 | External capacitor unit to extend Hold-up time. (Capacitance : 5,040uF) |
- | ||
CR-HUT502-2 | External capacitor unit to extend Hold-up time. (Capacitance : 5,040uF) |
- |