Features of SNTUNS50F12
• AC-DC converter, SNTUNS50/100F series includes TUNS50/100F series.• Universal input(AC85-264V)
• Power factor correction
• Harmonic attenuator (Complies with IEC61000-3-2)
• Built-in Inrush current , overcurrent, overvoltage and thermal protection
Ordering Information and Options
SNTUN(1) S(2) 50(3) F(4) 05(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
J: Connector type
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ * | |
Output | Wattage | 50.4W |
Voltage/Current | 12V 4.2A | |
Adjustable Voltage Range | 10.80 - 13.20V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | 13.90 - 16.35V | |
Remote ON/OFF | Not provided | |
Remote Sensing | Not provided | |
Others | - | |
Operating Temperature/Humidity | -20 to +95℃ (On aluminum base plate) , 20 - 95%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B | |
High Attenuation | Complies with IEC61000-3-2 (Class A) * | |
Others | Dimensions (WxHxD) | 50x36x150mm [1.97x1.42x5.91 inches] |
Weight | 230g max | |
Cooling Method | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) | |
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.