Features of R10A-24
• Small size and light• Built-in inrush current, overcurrent and overvoltage protection circuits
Ordering Information and Options
R(1) 10A(2) - 5(3) - □(4)
(1) Series name(2) Output wattage
(3) Output voltage
(4) Optional
G: Low leakage current
J: Connector type
N: with Cover
Specification
| Contents | Specifications | |
|---|---|---|
| Input Voltage | AC85 - 132V 1Φ or DC90 - 170V(at ACIN 90V, Io=80%) | |
| Output | Wattage | 12W |
| Voltage/Current | 24V 0.5A | |
| Adjustable Voltage Range | 21.6 - 26.4V | |
| Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically (ACIN 100V) |
| Overvoltage Protection | Works over 115% of rating (By zener diode clamping) | |
| Remote ON/OFF | - | |
| Remote Sensing | - | |
| Others | - | |
| Operating Temperature/Humidity | -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
| Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL Complies with DEN-AN |
| Conducted Noise | Complies with FCC-B, VCCI-B | |
| High Attenuation | - | |
| Others | Dimensions (WxHxD) | 26x68x68mm |
| Weight | 150g max | |
| Cooling Method | Convection | |
| Warranty Period | 3-year | |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
| Technical Data | ||
|---|---|---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.