PCA1000F-12

Released 2019

Features of PCA1000F-12

• Low profile (41mm, 1.61inch=meet to 1U height)
• Universal input 85 - 264VAC
• Output derating required (85V - 90VAC)
• For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 12V 0.1A (Voltage variable range 5 - 12V)
• Constant current regulation
• Output voltage can be varied to near 0V
• With various alarms
• Parallel operation possible
• N+1 Parallel Redundancy Operation possible
• Monitoring function by communication and various setting values can be changed

Ordering Information and Options

PC(1) A(2) 1000(3) F(4) - (5) - (6) 



(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating
  G: Low leakage current
  T: Terminal Block Style
    (Only 24V,32V and 48V)
  I: with PMBus interface
  F2: Reverse Fan direction
  P3: Master/slave operation
  W1: Alarm specification
For option details, refer to instruction manual 7.1.

Recommended EMI Filters

Specification

Contents Specifications
Input Voltage 85 - 264VAC 1Φ *
Output Wattage 1056W
Voltage/Current 12V 88A
Adjustable  Voltage Range 7.20 - 14.40V
Protection Circuit And Others Overcurrent Protection Works over 105% of rated current and recovers automatically
Overvoltage Protection 15.00 - 16.80V
Remote ON/OFF Provided
Remote Sensing Provided
Others -
Operating Temperature/Humidity -20 to +70℃ (Required Derating) , 20 - 90%RH (Non condensing)*
Safety And Noise Regulations Agency Approvals (At only AC input) UL62368-1, C-UL(CSA62368-1),EN62368-1, ANSI/AAMI ES60601-1, EN60601-1 3rd*
Conducted Noise Complies with FCC Part15 classA, VCCI-A, CISPR32-A, EN55011-A, EN55032-A
High Attenuation Complies with IEC61000-3-2 *
Others Dimensions (WxHxD) 102×41×178mm [4.02x1.61x7.01 inches] (without terminal block and screw)
Weight 1.2kg max
Cooling Method Forced cooling (internal fan)
Warranty Period 5-year (Refer to Instruction Manuals)
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.

Optional Parts

Category Part Number Description PDF DXF
Harness
H-PA-14 Harness for serial operation. -
H-PA-15 Harness for parallel operation and N+1 parallel redundancy operation. -
H-SN-48 Harness for using all functions of CN1 and CN2. -
H-SN-49 Harness for using all functions except remote sensing of CN1 and CN2. -
H-SN-50 Harness for using all functions of CN3. -
H-SN-51 Harness for using all functions of CN4. -
H-SN-52 Harness for using example remote ON/OFF circuit C. -
H-SN-53 Harness for using in slave setting of mater-slave operation. -
H-SN-54 Harness for using in effective setting of external output voltage adjustment. -
H-SN-66 Harness for using PMBus communication (-I option) -