Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of PBA50F-3R3
• Super small-size & light weight• Harmonic attenuator (Complies with IEC61000-3-2): except PBA1500T
• Universal input (AC85 - 264V): PBA1500T AC170-264V 3Φ
• Efficiency increased with synchronous rectification technology (PBA50F - 150F)
• Variety of option (PBA10F - 150F, PBW15F - 50F)
• Parallel operation and Parallel redundancy operation (PBA300F - 1500F, PBA1500T)
• Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T)
Ordering Information and Options
PB(1) A(2) 50(3) F(4) - 5(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current (0.15mA max/ACIN 240V)
E: Low leakage current and EMI class A (0.5mA max/ACIN 240V)
T: Vertical terminal block
J1: VH (J.S.T.) connector type
R: with Remote ON/OFF
N: with Cover (Only 24V UL508 is acquired)
N1: with DIN rail and Cover
V: Output voltage setting potentiometer externally
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ or DC120 - 370V * | |
Output | Wattage | 33W |
Voltage/Current | 3.3V 10A | |
Adjustable Voltage Range | 2.85 - 3.63V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rated current and recovers automatically |
Overvoltage Protection | 4.00 - 5.25V | |
Remote ON/OFF | Optional (Required external power source) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
Conducted Noise | Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B | |
High Attenuation | Complies with IEC61000-3-2 * | |
Others | Dimensions (WxHxD) | 31x82x120mm [1.22x3.23x4.72 inches] (without terminal block) |
Weight | 280g max (with cover: 325g max) | |
Cooling Method | Convection | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Attachment Plate, Attachment for Replacement, DIN Rail Attachment Plate, Harness
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Attachment |
F-PBA50-1 | Attachment plate to facilitate mounting. (For mounting at the bottom) |
||
F-PBA50-2 | Attachment plate to facilitate mounting. (For mounting at the front side/back side) |
|||
DIN rail Attachment Plate |
FD-PBA50 | DIN rail attachment plate. (DIN rail width : 35mm) |
||
Harness |
H-IN-3 | Mating harness for input with J1 option. (Mfr : J.S.T.) | - | |
H-IN-27 | Mating harness for input with J1 option. (Mfr : J.S.T.) | - | ||
H-OU-9 | Mating harness for output with J1 option. (Mfr : J.S.T.) | - | ||
H-RC-1 | Harness for using option : -R. | - | ||
H-SN-18 | Harness for using option : -V. | - |