| Warranty Period | 5-year (Refer to Instruction Manuals) |
|---|
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of PBA100F-9
• Super small-size & light weight• Harmonic attenuator (Complies with IEC61000-3-2): except PBA1500T
• Universal input (AC85 - 264V): PBA1500T AC170-264V 3Φ
• Efficiency increased with synchronous rectification technology (PBA50F - 150F)
• Variety of option (PBA10F - 150F, PBW15F - 50F)
• Parallel operation and Parallel redundancy operation (PBA300F - 1500F, PBA1500T)
• Fan alarm, Remote ON/OFF and other functions (PBA300F - 1500F, PBA1500T)
Ordering Information and Options
PB(1) A(2) 100(3) F(4) - 5(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current (0.15mA max/ACIN 240V)
E: Low leakage current and EMI class A (0.5mA max/ACIN 240V)
T: Vertical terminal block
J1: VH (J.S.T.) connector type (Only -12, -15, -24, -36, -48)
R: with Remote ON/OFF
N: with Cover (Only 24V UL508 is acquired)
N1: with DIN rail and Cover
V: Output voltage setting potentiometer externally
Recommended EMI Filters
Specification
| Contents | Specifications | |
|---|---|---|
| Input Voltage | AC85 - 264V 1Φ or DC120 - 370V * | |
| Output | Wattage | 94.5W |
| Voltage/Current | 9V 10.5A | |
| Adjustable Voltage Range | 7.50 - 10.0V | |
| Protection Circuit And Others | Overcurrent Protection | Works over 105% of rated current and recovers automatically |
| Overvoltage Protection | 11.5 - 14.0V | |
| Remote ON/OFF | Optional (Required external power source) | |
| Remote Sensing | Optional (Only -3R3, -5 Option -K) | |
| Others | - | |
| Operating Temperature/Humidity | -10 to +71℃ (Required Derating) , 20 - 90%RH (Non condensing) | |
| Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
| Conducted Noise | Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B | |
| High Attenuation | Complies with IEC61000-3-2 * | |
| Others | Dimensions (WxHxD) | 32x93x147mm [1.26x3.66x5.79 inches] (without terminal block) |
| Weight | 440g max (with cover: 500g max) | |
| Cooling Method | Convection | |
| Warranty Period | 5-year (Refer to Instruction Manuals) | |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
| Technical Data | ||
|---|---|---|
| CAD Data | DXF | |
| 3D CAD Data | STEP | |
| IGES | ||
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Attachment Plate, Attachment for Replacement, DIN Rail Attachment Plate, Harness
| Category | Part Number | Description | DXF | |
|---|---|---|---|---|
Attachment |
F-PBA100-1 | Attachment plate to facilitate mounting. (For mounting at the bottom) |
||
| F-PBA100-2 | Attachment plate to facilitate mounting. (For mounting at the front side/back side) |
|||
DIN rail Attachment Plate |
FD-PBA100 | DIN rail attachment plate. (DIN rail width : 35mm) |
||
Harness |
H-IN-3 | Mating harness for input with J1 option. (Mfr : J.S.T.) | - | |
| H-IN-27 | Mating harness for input with J1 option. (Mfr : J.S.T.) | - | ||
| H-OU-18 | Mating harness for output with J1 option. (Mfr : J.S.T.) | - | ||
| H-RC-1 | Harness for using option : -R. | - | ||
| H-SN-1 | Harness for using option : -K. | - | ||
| H-SN-18 | Harness for using option : -V. | - |