PAA600F-12

Discontinued (May, 2015)

Released 1996

Recommended Model for Replacement

Type Product Name Released Catalog
Instruction Manuals
Documents for replacement
Enclosed type PBA600F-12 2003
  • Catalog
  • Instruction Manuals
  • Enclosed type PJA600F-12 2017
  • Catalog
  • Instruction Manuals
    • * For further information and how to use, please see in Cosel product catalog.

    Features of PAA600F-12

    -

    Ordering Information and Options

    PAA(1)    600(2)    F(3)    -    5(4)    -    (5)  

    (1) Series name
    (2) Output wattage
    (3) Universal input
    (4) Output voltage
    (5) Optional
      C: with Coating
      G: Low leakage current
      R: Positive logic control
      W: with Alarm signal

    Specification

    Contents Specifications
    Input Voltage AC85 - 264V 1Φ
    Output Wattage 636W
    Voltage/Current 12V 53A
    Adjustable  Voltage Range ±10%
    Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically
    Overvoltage Protection Works at 115 - 140% of rating
    Remote ON/OFF Provided
    Remote Sensing Provided
    Others -
    Operating Temperature/Humidity -10 to +65℃, 20 - 90%RH (Non condensing) *
    Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
    Conducted Noise Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
    High Attenuation Complies with IEC61000-3-2
    Others Dimensions (WxHxD) 190x92x200mm (without terminal block and screw)
    Weight 4.0kg max
    Cooling Method Forced cooling (internal fan)
    Warranty Period 3-year
    • * For further information and how to use, please see in Cosel product catalog.

    Documents Download

    • * For another documents aren't listed, please feel free to contact to a Cosel representative.
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.