PAA300F-3

Discontinued (May, 2015)

Released 1996

Features of PAA300F-3

-

Ordering Information and Options

PAA(1)    300(2)    F(3)    -    5(4)    -    (5)  

(1) Series name
(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
  C: with Coating
  G: Low leakage current
  R: Positive logic control
  W: with Alarm signal

Specification

Contents Specifications
Input Voltage AC85 - 264V 1Φ
Output Wattage 180W
Voltage/Current 3V 60A
Adjustable  Voltage Range 2.85 - 3.45V
Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically
Overvoltage Protection 4.00 - 5.25V
Remote ON/OFF Provided
Remote Sensing Provided
Others -
Operating Temperature/Humidity -10 to +65℃, 20 - 90%RH (Non condensing) *
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, EN60950-1, EN50178, CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1
Conducted Noise Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
High Attenuation Complies with IEC61000-3-2
Others Dimensions (WxHxD) 120x92x190mm (without terminal block and screw)
Weight 2.2kg max
Cooling Method Forced cooling (internal fan)
Warranty Period 3-year
  • * For further information and how to use, please see in Cosel product catalog.

Documents Download

  • * For another documents aren't listed, please feel free to contact to a Cosel representative.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.