Features of MHFS31212
• Industry Standard SIP8• Wide input range 4.5-18VDC
• I/O isolation voltage AC3,000V , DC4,200V (1 minute)
• Built-in overcurrent protection circuits (recovers automatically)
• For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd)
Medical Isolation Grade 2MOOP (250VAC)
• Built-in remote ON/OFF
• High reliability : not built-in aluminum and tantalum electrolytic capacitor
Ordering Information and Options
MHF(1) S(2) 3(3) 24(4) 05(5)
(1) Series name(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | 4.5 - 18VDC | |
Output | Wattage | 3W |
Voltage/Current | 12V 0.25A | |
Adjustable Voltage Range | Fixed (TRM pin open) Available to adjust -5% / +20% by external variable resister | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | - | |
Remote ON/OFF | Provided (Negative logic L: ON, H: OFF) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -40 to +85℃, 20 to 95%RH (Non condensing) (Required derating) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, EN62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), ANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1) |
Conducted Noise | - | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 22.0x12.0x9.5mm [0.87x0.48x0.38 inches] |
Weight | 7g max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 5-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.