Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*New model available, LHA series, High efficiency, Low noise & Low profile.
Recommended Model for Replacement
Type | Product Name | Released | Catalog Instruction Manuals Documents for replacement |
|
---|---|---|---|---|
Open Frame type | LHP300F-30-Y | 2021 |
|
- * For further information and how to use, please see in Cosel product catalog.
Features of LFA300F-30-TY
• Small and compact PCB construction• Built-in inrush current, overcurrent and overvoltage protection circuits
• Harmonic attenuator (Complies with IEC61000-3-2)
• Universal input (AC85-264V)
• Power factor correction (LFA50F-300F)
• Built-in reducing standby power circuit (LFA10F, 15F)
Ordering Information and Options
LF(1) A(2) 300(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
H: with the function to be acceptable to output peak current (only 24V, 30V, 36V and 48V)
J: EP (Tyco Electronics) connector type (Except 3.3V and 5V)
J1: VH (J.S.T.) connector type (Except 3.3V and 5V)
R: with Remote ON/OFF
R2: with Remote ON/OFF
S: with Chassis
SNF: with Chassis & cover & fan (Only 5V, 12V and 24V)
T1: Horizontal terminal block
Please refer to Instruction manual 5.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ * | |
Output | Wattage | 330W |
Voltage/Current |
30V 10A Convection Cooling 30V 11A Forced Air Cooling |
|
Adjustable Voltage Range | 27.00 - 33.00V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically |
Overvoltage Protection | 34.50 to 42.00V | |
Remote ON/OFF | Option (Refer to Instruction Manual) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +70℃, 20 - 90%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , EN62368-1 Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B | |
High Attenuation | Complies with IEC61000-3-2 (Class A) * | |
Others | Dimensions (WxHxD) | 95x52.5x222mm [3.74x2.07x8.74 inches] |
Weight | 810g max (with chassis & cover: 1,270g max) | |
Cooling Method | Convection/Forced air (Refer to Instruction Manual 3.1 and 3.2) * | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-IN-13 | Mating harness for input of the connector type power supply. (Mfr : Tyco Electronics) | - | |
H-IN-14 | Mating harness for input of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-OU-11 | Mating harness for output of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-OU-12 | Mating harness for output of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-OU-31 | Mating harness for output of the connector type power supply. (Mfr : Tyco Electronics) | - | ||
H-OU-32 | Mating harness for output of the connector type power supply. (Mfr : Tyco Electronics) | - | ||
H-RC-1 | Harness for using option : -R. | - |