Features of LCA100S-3
• Small and compact PCB construction• UL recognized, CSA certified
• Built-in inrush current, overcurrent and overvoltage protection circuits
Ordering Information and Options
LC(1) A(2) 100(3) S(4) - 5(5) - □(6)
(1) Series name(2) 100/120V input
(3) Output wattage
(4) Single output
(5) Output voltage
(6) Optional *
C: with Coating
G: Low leakage current
S: with Chassis
SN: with Chassis & cover
Y: with Potentiometer
*Please contact us about safety approvals for the model with option.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 132V 1Φ or DC110 - 170V | |
Output | Wattage | 60W |
Voltage/Current | 3V 20A | |
Adjustable Voltage Range | 2.85 - 3.6V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating (works over 105% of peak current at option -H) and recovers automatically |
Overvoltage Protection | 4.00 - 5.25V | |
Remote ON/OFF | Not provided | |
Remote Sensing | Not provided | |
Others | - | |
Operating Temperature/Humidity | -10 to +60℃, 20 - 90%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 62x32x222mm |
Weight | 370g max(without chassis and cover) | |
Cooling Method | Convection | |
Warranty Period | 2-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data |
---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-IN-5 | Mating harness for input of the connector type power supply. (Mfr : J.S.T.) | - | |
H-IN-10 | Mating harness for input of the connector type power supply. (Mfr : J.S.T.) | - | ||
H-OU-10 | Mating harness for output with J option. (Mfr : J.S.T.) | - |