Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
Features of HCA3500TF-48
Fanless (Conduction cooling)Low profile (65mm, 2.56 inch = Meet 1.5U height)
Wide input voltage range : 3φ 180-528VAC
Built-in AUX power 12V 1A
Parallel Operation / N+1 Parallel Redundancy Operation
High efficiency
Built-in Alarms
Built-in ORING MOSFET
Complies with SEMI F47
Ordering Information and Options
HC(1) A(2) 3500(3) TF(4) - □□(5) - □(6)
(1)Series name
(2)Single output
(3)Output wattage
(4)3 phase full range input
(5)Output voltage
(6)Optional
R:with Remote ON/OFF Positive logic control
G:Low leakage current
T1 : Different shaped output terminal
I4:with MODBUS interface
Specification is changed at option, refer to Instruction manual.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | 180 - 528VAC 3Φ * | |
Output | Wattage | 3504W |
Voltage/Current | 48V 73A | |
Adjustable Voltage Range | 33.60 to 55.20V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating (Recovers automatically, Hiccup overcurrent) |
Overvoltage Protection | 59.04 to 67.20V | |
Remote ON/OFF | Provided | |
Remote Sensing | Provided | |
Others | Auxiliary output, Parallel operation, Warning signal, Alarm signal | |
Operating Temperature/Humidity |
0 to +55℃ (Baseplate temperature), -10 to +70℃ (Ambient temperature), 20 - 90%RH(Non condensing) * |
|
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, C-UL(equivalent to CAN/CSA-C22.2 No. 62368-1), EN62368-1 |
Conducted Noise | Complies with FCC Part15-A, FCC Part18-A, VCCI-A, CISPR11-A, CISPR32-A, EN55011-A, EN55032-A | |
High Attenuation | - | |
Others | Dimensions (WxHxD) |
110×65×420mm [4.33×2.56×16.54 inches] (without terminal block) |
Weight | 5kg max | |
Cooling Method | Conduction cooling | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness, Heat sink (Water-cooled)
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-PA-18 | Harness for parallel operation.(Both side housing) | - | |
H-SN-74 | Harness for using functions of CN1 and CN2.(Single side housing) | - | ||
H-SN-75 | Harness for using functions of CN3 without digital communication. (Single side housing) | - | ||
H-SN-76 | Harness for using functions of CN3. (Single side housing) (For -I4 option) |
- | ||
Heat sink |
F-HCA-F1 | Heatsink (water cooled) for HCA3500TF. | - |