DPA500F-360

Discontinued (May, 2018)

Released 1995

Recommended Model for Replacement

Type Product Name Released Catalog
Instruction Manuals
Documents for replacement
Bus Converter・Power Module type DPG500 2010
  • Catalog
  • Instruction Manuals
  • Documents for replacement
  • Bus Converter・Power Module type DPG750 2010
  • Catalog
  • Instruction Manuals
  • Documents for replacement
    • * For further information and how to use, please see in Cosel product catalog.

    Features of DPA500F-360

    • Harmonic attenuator (Complies with IEC61000-3-2)
    • High efficiency 90% (AC100V) , 95% (AC200V)
    • Universal input voltage(AC85 - 264V)
    • Built-in inrush current protection (No need for external resistor)
    • Parallel operation is possible (Built-in current balancing function)
    • Built-in overvoltage and thermal protection circuits
    • Inverter operation monitoring (IOG)
    • Power-ready singnal (PR)
    • Auxiliary power supply for external signal (AUX)
    • Ideal for distributed power systems

    Ordering Information and Options

    DA(1)  A(2)  500(3)  F(4)  -  360(5)  

    (1) Series name
    (2) Single output
    (3) Output wattage
    (4) Universal input
    (5) Output voltage

    Specification

    Contents Specifications
    Input Voltage AC85 - 264V
    AC170 - 264V
    Output Wattage 500W, 750W
    Voltage/Current 300 - 360V
    Adjustable  Voltage Range -
    Protection Circuit And Others Overcurrent Protection -
    Overvoltage Protection DC390 - 440V
    Remote ON/OFF -
    Remote Sensing -
    Others -
    Operating Temperature/Humidity -20 to +85℃ (Aluminum base plate) , 20 - 95%RH (Non condensing) *
    Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, CSA C22.2 No.60950-1, EN60950-1, EN50178 Complies with DEN-AN and IEC60950-1
    Conducted Noise -
    High Attenuation -
    Others Dimensions (WxHxD) 58x12.7x130mm
    Weight 150g max
    Cooling Method Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink)
    Warranty Period 3-year
    • * For further information and how to use, please see in Cosel product catalog.

    Documents Download

    Technical Data
    • * For another documents aren't listed, please feel free to contact to a Cosel representative.
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.