Warranty Period | 5-year |
---|
* Please note that the unit's internal components is damaged if the output is short-circuit.
Features of DPG500
• High efficiency 93% (AC100V) , 96% (AC200V)• Universal input voltage (AC85 - 264V)
• Built-in inrush current protection
• Enable signal (ENA)
• Auxiliary power supply for external signal (AUX)
• Harmonic attenuator (Complies with IEC61000-3-2)
Ordering Information and Options
DPG(1) 750(2)
(1) Series name(2) Output power
500: 500W (ACIN 200V)
750: 750W (ACIN 200V)
Specification
Contents | Specifications | |
---|---|---|
Input Voltage |
AC85 - 264V 1Φ AC170 - 264V 1Φ |
|
Output | Wattage | 300W, 500W |
Voltage/Current | 360V | |
Adjustable Voltage Range | - | |
Protection Circuit And Others | Overcurrent Protection | - |
Overvoltage Protection | DC400 - 450V The power factor corrector function stops | |
Remote ON/OFF | - | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -40 to +100℃ (On aluminum base plate) , 20 - 95%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL60950-1, C-UL, EN62368-1 Complies with DEN-AN and IEC60950-1 |
Conducted Noise | - | |
High Attenuation | Complies with IEC61000-3-2 * | |
Others | Dimensions (WxHxD) | 58.4x12.7x61mm [2.3x0.5x2.4 inches] |
Weight | 100g max | |
Cooling Method | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) | |
Warranty Period | 5-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.