Rated Input: DC60 - 160V
Rated Output Wattage: 100W
Rated Output Voltage: 5V,12V,15V,24V
Rated Output Wattage: 100W
Rated Output Voltage: 5V,12V,15V,24V
Warranty Period | 5-year |
---|
When remote ON/OFF is not used, short RC and -VIN.
When the output voltage adjustment is not used,
open the TRM pin respectively.
Features of DHS100A
• Compact DC-DC Converter, "BRICK SIZE" which has been standard size for Telecommunication Market• High efficiency
• High density
• High reliability: not built-in aluminum and tantalum electrolytic capacitor
• Built-in overcurrent, overvoltage and thermal protection circuits
• Built-in remote ON/OFF
• For Railway (complies with EN50155 required vibration and impact tests)
Ordering Information and Options
DH(1) S(2) 100(3) A(4) 05(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) A: DC60 - 160V
(5) Output voltage
(6) Optional
T: with Mounting hole
(φ3.4 thru)
Product Line-up
Product Name | Output Wattage | Output Voltage・Current |
---|---|---|
DHS100A05 | 100.0W | 5V 20A |
DHS100A12 | 100.8W | 12V 8.4A |
DHS100A15 | 100.5W | 15V 6.7A |
DHS100A24 | 100.8W | 24V 4.2A |
- * For further information and how to use, please see in Cosel product catalog.
Optional Parts
Heat sink
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Heat sink |
F-QB-F1 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) | - | |
F-QB-F2 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) | - | ||
F-QB-F3 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) | - | ||
F-QB-F4 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) | - | ||
F-QB-F5 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Horizontal style) | - | ||
F-QB-F6 | Heatsink for TUNS50, CQHS300, CQHS350, DHS50, DHS100 series. (Vertical style) | - |