    Features of CQS24120-12

    • Compact DC-DC Converter, "BRICK SIZE" which has been standard size for Telecommunication Market
    • High efficiency
    • High density
    • High reliability: not built-in aluminum and tantalum electrolytic capacitor
    • Built-in overcurrent, overvoltage and thermal protection circuits
    • Built-in remote ON/OFF

    Ordering Information and Options

    CQ(1)  S(2)  48(3)  018(4)  -  50(5)  -  (6)  

    (1) Series name
    (2) Single output
    (3) Input voltage
      24: DC18 - 36V
      48: DC36 - 76V
    (4) Output voltage
      015: 1.5V
      018: 1.8V
      025: 2.5V
      033: 3.3V
      050: 5V
      120: 12V
      150: 15V
    (5) Output current
    (6) Optional
      R: with Remote ON/OFF
        Positive logic control
      V: Output voltage setting ±1%
      N: Auto restart from thermal protection

    Specification

    Contents Specifications
    Input Voltage DC18 - 36V
    Output Wattage 144.0W
    Voltage/Current 12V 12A
    Adjustable  Voltage Range Fixed (TRM pin open), adjustable by external resistor
    -20%/+10%
    Protection Circuit And Others Overcurrent Protection Works over 105% of rating, low voltage protection (shut down) function is built-in.
    Overvoltage Protection 117% - 127%
    Remote ON/OFF Provided (Negative logic L: ON, H: OFF)
    Remote Sensing Provided
    Others -
    Operating Temperature/Humidity -40 to +85℃, 20 to 95%RH (Non condensing) *
    Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL (CSA60950-1) , EN62368-1
    Conducted Noise -
    High Attenuation -
    Others Dimensions (WxHxD) 57.9x8.5x36.8mm [2.28x0.33x1.45 inches]
    Weight 40g max
    Cooling Method Convection/Forced air
    Warranty Period 5-year
    • * For further information and how to use, please see in Cosel product catalog.

    Documents Download

    Technical Data
    CAD Data DXF
    • * For another documents aren't listed, please feel free to contact to a Cosel representative.
    Table1 Product Status Information
    No. Product Status Definition
    1 New Product New Product. Recommended for new design.
    2 Recommended Recommended for new design.
    3 blank Product in mass production
    4 NRND Not recommended for new design.
    5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
    6 Discontinued LTB order is no longer available.