Single phase 250VAC 30A
Low leakage current type
1-stage filter
Low leakage current type
1-stage filter
Warranty Period | 5-year |
---|
The terminal cover is retracted inside the unit.
DIN rail installation type is option.
Features of NAM-30
Push down type terminal blockOrdering Information and Options
NAM(1) - 30(2) - 000(3) - □(4)
(1) Model Name(2) Rated Current
(3) Line to ground capacitor code
Refer to Product Line-up.
* When the line to ground capacitor code is different, the attenuation characteristic is
different.
(4) Options
D:DIN rail installation type
* The dimensions change when the option is set. Refer to External view.
Product Line-up
Product Name | Leakage Current* | Line to ground capacitor (nominal value) |
---|---|---|
NAM-30-000 | 5μA/10μA max | Not Provided |
NAM-30-101 | 12.5μA/25μA max | 100pF |
NAM-30-221 | 25μA/50μA max | 220pF |
NAM-30-331 | 37.5μA/75μA max | 330pF |
NAM-30-471 | 50μA/100μA max | 470pF |
- * Input 125/250VAC 60Hz
- Catalog (Including Dimensions)
- Instruction Manuals (Including attenuation characteristics)
- Technical Notes
Specification
Contents | Specifications | |
---|---|---|
Rated Voltage | AC 1 φ 250V/DC250V | |
Rated Current | 30A | |
Operating Temperature | -40 to +85℃ (Refer to Derating Curve) | |
Agency Approvals |
UL1283, CSA C22.2 No.8 (C-UL) , DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input) |
|
Others | Dimensions (WxHxD) |
53x41x92 mm [2.09x1.61x3.62 inches] (Option: -D refer to external view) |
Weight | 300g max | |
Warranty Period | 5-year |
- * For further information and how to use, please see in Cosel product catalog.
Circuit Diagram
Derating Curve
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Similar Model (Rated Voltage and Current)
Features | Model Name | Released | Catalog Instruction Manuals |
|
---|---|---|---|---|
Small size, Low leakage current type, 1-stage filter |
EAM-30 | 2010 |
Catalog Instruction Manuals |
|
Ultra high-attenuation type, 1-stage filter |
NAH-30 | 2006 |
Catalog Instruction Manuals |
|
Low leakage current type, High-attenuation type, 2-stage filter |
NBM-30 | 2007 |
Catalog Instruction Manuals |
|
Ultra high-attenuation and broadband, 2-stage filter |
NBH-30 | 2007 |
Catalog Instruction Manuals |
- * For further information and how to use, please see in Cosel product catalog.