Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
* Please remove short piece on CN3 to enable remote ON/OFF function.
Features of STMGFS80243R3
• Isolated unit type DC-DC converter• Wide input voltage DC9-36V
• Available case cover (option)
• Available DIN rail attachment (option)
• Built in Overcurrent protection (recovery automatically)
• Built in Overvoltage protection
• Built in Remote ON/OFF
• Output volatge is adjustable for ±10%
Ordering Information and Options
STMGF(1) S(2) 30(3) 24(4) 05(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
R: with Remote ON/OFF
(Positive logic control)
N1: with case cover
N2: with DIN rail installation type
N3: with cover(plastic) and DIN rail installation type
* When the option is set specifications may vary
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | DC9 ~ 36V | |
Output | Wattage | 59.4W |
Voltage/Current | 3.3V 18A | |
Adjustable Voltage Range | 2.97 - 3.63V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | Works over 115 to 140% of rating | |
Remote ON/OFF | Provided (Negative logic L: ON, H: OFF) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -20 to +70℃, 20 to 95%RH (Non condensing) (Required Derating) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, C-UL(CSA62368-1), EN62368-1 Complies |
Conducted Noise | - | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 52x29x117mm [2.05x1.14x4.61 inches] |
Weight | 170g max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.