| Warranty Period | 3-year |
|---|
*For connection of loads except the series DBS, please contact Cosel development department.
*Never make a short-circuit between the output pins. It may severely damage the unit.
*No alternatives available
Features of STA5000T
• Equipped with improved power factor, open phase detection and overheating detection circuits• Can optionally feature sequence unit for DC-DC converter ON/OFF control
• Conducted noise EN55022 class B (When combined with recommended filter + DBS series unit)
• Small and light weight
Ordering Information and Options
STA(1) 5000(2) T(3) - □(4)
(1) Series name(2) Output wattage
(3) Triple input phase
(4) Optional
R: with Sequence unit
Specification
| Contents | Specifications | |
|---|---|---|
| Input Voltage | AC170 - 264V 3Φ(Rated Input Voltage : AC200V) | |
| Output | Wattage | 5000W |
| Voltage/Current | DC230 - 370V | |
| Adjustable Voltage Range | - | |
| Protection Circuit And Others | Overcurrent Protection | - |
| Overvoltage Protection | - | |
| Remote ON/OFF | - | |
| Remote Sensing | - | |
| Others | - | |
| Operating Temperature/Humidity | -10 - 50℃ Forced air | |
| Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , IEC60950-1 |
| Conducted Noise | Complies with FCC-B, CISPR22-classB, EN55022-B | |
| High Attenuation | - | |
| Others | Dimensions (WxHxD) | 131.5x144x250mm (without terminal block and screw) |
| Weight | 5kg max | |
| Cooling Method | Forced air (Require external fan) | |
| Warranty Period | 3-year | |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
| Technical Data | ||
|---|---|---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.