SPLFA50F-12

Discontinued (November, 2020)

Released 2011

Features of SPLFA50F-12

• Universal input (AC85-264V)
• Approved with DEN-AN (at AC100V-120V input)
• Small and compact size
• Harmonic attenuator (Complies with IEC61000-3-2)
• Power factor correction (SPLFA50F-75F-100F-150F)
• Built-in inrush current, overcurrent and overvoltage protection circuits

Ordering Information and Options

SPLF(1)  A(2)  50(3)  F(4)  -  (5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
  C: with Coating

Specification

Contents Specifications
Input Voltage AC85 - 264V 1Φ *
Output Wattage 51.6W
Voltage/Current 12V 4.3A
Adjustable  Voltage Range -
Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically
Overvoltage Protection 13.80 to 16.80V
Remote ON/OFF -
Remote Sensing -
Others -
Operating Temperature/Humidity -10 to +50℃, 20 - 90%RH (Non condensing) *
Safety And Noise Regulations Agency Approvals (At only AC input) DEN-AN
Conducted Noise Complies with DEN-AN
High Attenuation Complies with IEC61000-3-2 (class A)
Others Dimensions (WxHxD) 61x36x174mm [2.40x1.42x6.85 inches]
Weight 440g max
Cooling Method Convection
Warranty Period 3-year
  • * For further information and how to use, please see in Cosel product catalog.

Block Diagram

Documents Download

Technical Data
CAD Data DXF
3D CAD Data STEP
IGES
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.