Warranty Period | 3-year |
---|
*No alternatives available
Features of SPLFA100F-12
• Universal input (AC85-264V)• Approved with DEN-AN (at AC100V-120V input)
• Small and compact size
• Harmonic attenuator (Complies with IEC61000-3-2)
• Power factor correction (SPLFA50F-75F-100F-150F)
• Built-in inrush current, overcurrent and overvoltage protection circuits
Ordering Information and Options
SPLF(1) A(2) 100(3) F(4) - □(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 264V 1Φ * | |
Output | Wattage | 102.0W |
Voltage/Current | 12V 8.5A | |
Adjustable Voltage Range | - | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | 13.80 to 16.80V | |
Remote ON/OFF | - | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +50℃, 20 - 90%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | DEN-AN |
Conducted Noise | Complies with DEN-AN | |
High Attenuation | Complies with IEC61000-3-2 (class A) | |
Others | Dimensions (WxHxD) | 73x42x197mm [2.87x1.65x7.76 inches] |
Weight | 670g max | |
Cooling Method | Convection | |
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.