R25A-15

Discontinued (May, 2016)

Released 1998

Features of R25A-15

• Small size and light
• Built-in inrush current, overcurrent and overvoltage protection circuits

Ordering Information and Options

R(1)  25A(2)  -  5(3)  -  (4)  

(1) Series name
(2) Output wattage
(3) Output voltage
(4) Optional
  C: with Coating
  G: Low leakage current
  J: Connector type
  N: with Cover

Specification

Contents Specifications
Input Voltage AC85 - 132V 1Φ or DC110 - 170V
Output Wattage 25.5W
Voltage/Current 15V 1.7A
Adjustable  Voltage Range 13.5 - 16.5V
Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically (ACIN 100V)
Overvoltage Protection Works at 115 - 140% of rating
Remote ON/OFF -
Remote Sensing -
Others -
Operating Temperature/Humidity -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL Complies with DEN-AN
Conducted Noise Complies with FCC-B, VCCI-B
High Attenuation -
Others Dimensions (WxHxD) 31x69x104mm
Weight 250g max (without cover)
Cooling Method Convection
Warranty Period 3-year
  • * For further information and how to use, please see in Cosel product catalog.

Documents Download

Technical Data
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.