Features of R150U-18
• Small size and light• Built-in inrush current, overcurrent and overvoltage protection circuits
Ordering Information and Options
R(1) 150(2) □(3) - 5(4) - □(5)
(1) Series name(2) Output wattage
(3) UL recognized, TÜV approved, CSA certified
(4) Output voltage
(5) Optional
C: with Coating
G: Low leakage current
N: with Cover
Specification
| Contents | Specifications | |
|---|---|---|
| Input Voltage | AC85 - 132V 1Φ or DC110 - 170V | |
| Output | Wattage | 153W |
| Voltage/Current | 18V 8.5A | |
| Adjustable Voltage Range | 16.2 - 19.8V | |
| Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
| Overvoltage Protection | Works at 115 - 140% of rating | |
| Remote ON/OFF | - | |
| Remote Sensing | Provided | |
| Others | - | |
| Operating Temperature/Humidity | -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
| Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, CSA C22.2 No.60950-1, EN60950-1 Complies with DEN-AN and IEC60950-1 |
| Conducted Noise | Complies with FCC-B, VCCI-B | |
| High Attenuation | - | |
| Others | Dimensions (WxHxD) | 44.5x93x175mm |
| Weight | 900g max (without cover) | |
| Cooling Method | Convection | |
| Warranty Period | 3-year | |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
| Technical Data | ||
|---|---|---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.