Features of R150U-15
• Small size and light• Built-in inrush current, overcurrent and overvoltage protection circuits
Ordering Information and Options
R(1) 150(2) □(3) - 5(4) - □(5)
(1) Series name(2) Output wattage
(3) UL recognized, TÜV approved, CSA certified
(4) Output voltage
(5) Optional
C: with Coating
G: Low leakage current
N: with Cover
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 132V 1Φ or DC110 - 170V | |
Output | Wattage | 150W |
Voltage/Current | 15V 10A | |
Adjustable Voltage Range | 13.5 - 16.5V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | Works at 115 - 140% of rating | |
Remote ON/OFF | - | |
Remote Sensing | Provided | |
Others | - | |
Operating Temperature/Humidity | -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, CSA C22.2 No.60950-1, EN60950-1 Complies with DEN-AN and IEC60950-1 |
Conducted Noise | Complies with FCC-B, VCCI-B | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 44.5x93x175mm |
Weight | 900g max (without cover) | |
Cooling Method | Convection | |
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data |
---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.