R150U-12

Discontinued (May, 2016)

Released 1993

Features of R150U-12

• Small size and light
• Built-in inrush current, overcurrent and overvoltage protection circuits

Ordering Information and Options

R(1)  150(2)  (3)  -  5(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) UL recognized, TÜV approved, CSA certified
(4) Output voltage
(5) Optional
  C: with Coating
  G: Low leakage current
  N: with Cover

Specification

Contents Specifications
Input Voltage AC85 - 132V 1Φ or DC110 - 170V
Output Wattage 156W
Voltage/Current 12V 13A
Adjustable  Voltage Range 10.8 - 13.2V
Protection Circuit And Others Overcurrent Protection Works over 105% of rating and recovers automatically
Overvoltage Protection Works at 115 - 140% of rating
Remote ON/OFF -
Remote Sensing Provided
Others -
Operating Temperature/Humidity -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, CSA C22.2 No.60950-1, EN60950-1 Complies with DEN-AN and IEC60950-1
Conducted Noise Complies with FCC-B, VCCI-B
High Attenuation -
Others Dimensions (WxHxD) 44.5x93x175mm
Weight 900g max (without cover)
Cooling Method Convection
Warranty Period 3-year
  • * For further information and how to use, please see in Cosel product catalog.

Documents Download

Technical Data
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.
Table1 Product Status Information
No. Product Status Definition
1 New Product New Product. Recommended for new design.
2 Recommended Recommended for new design.
3 blank Product in mass production
4 NRND Not recommended for new design.
5 To be discontinued PDN (Product Discontinuation Notice) is issued and LTB (Last Time Buy) is under consideration.
6 Discontinued LTB order is no longer available.