Features of PMC100E-2
• Small size• Universal input voltage
(PMC15E, 30E: AC85 - 264V PMC50E, 75E, 100E: AC85 - 132V/AC170 - 264V)
• Built-in inrush current and overcurrent protection circuits
• V1 isolated from V2 and V3
• Stabilized output voltage (V1, V2, V3)
Ordering Information and Options
PMC(1) 100(2) □(3) - 1(4) - □(5)
(1) Series name(2) Output wattage
(3) UL recognized, TÜV approved, CSA certified: E
(4) Output voltage combination
(5) Optional
G: Low leakage current
J: Connector type
N: with Cover
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 132V/170 - 264V 1Φ (User selectable) or DC220 - 370V | |
Output | Wattage | 102.5W |
Voltage/Current |
V1 :+5V 13.0A V2 :+15V 1.5A V3 :-15V 1.0A |
|
Adjustable Voltage Range |
5.00 - 5.25V Fixed Fixed |
|
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | Works at 115 - 140% of rating (+5V) | |
Remote ON/OFF | - | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +65℃, 20 - 95%RH (Non condensing) (Refer to DERATING CURVE) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, CSA1402C, EN60950-1, EN50178 Complies with IEC60950-1 and DEN-AN |
Conducted Noise | Complies with FCC-B | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 48x93x220mm (without terminal block and screw) |
Weight | 750g max | |
Cooling Method | Convection | |
Warranty Period | 3-year |