Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
Features of PCA600F-5
• Low profile (41mm, 1.61inch = meet 1U height)• DC input 88 - 370VDC possible
• Output derating required (85V - 90VAC/88V - 110VDC)
• For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd, IEC60601-1-2 4th Ed.)
• Medical Isolation Grade 2MOPP
• With AUX output 12V 0.1A (Voltage variable range 5 - 12V)
• Constant current function
• Output voltage can be adjusted to near 0V
• With various alarms
• Parallel Operation / N+1 Parallel Redundancy Operation possible
• Monitoring function and various setting values can be changed by communication
• Complies with SEMI F-47(Io:100%max at ACIN 200V, 70%max at ACIN 100V)
• Meets UL508 (Option: -T5)
Ordering Information and Options
PC(1) A(2) 600(3) F(4) - □(5) - □(6)
(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Optional
C: with Coating
G: Low leakage current
T: Terminal Block Style
(Only 12V,15V,24V,32V and 48V)
I: with PMBus interface
F2: Reverse air exhaust type
P3: Master-slave Operation
W1: Alarm function
T5: UL508
(Only 12V,15V,24V,32V and 48V)
For option details, refer to instruction manual 6.1.
3D product images are available.
Read Me First
Standard model (Bus bar) T: Terminal Block Style (Only 12V,15V,24V,32V and 48V)
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | 85 - 264VAC 1Φ * | |
Output | Wattage | 600W |
Voltage/Current | 5V 120A | |
Adjustable Voltage Range | 3.00 - 6.00V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rated current and recovers automatically |
Overvoltage Protection | 6.25 - 7.00V | |
Remote ON/OFF | Provided | |
Remote Sensing | Provided | |
Others | - | |
Operating Temperature/Humidity | -20 to +70℃ (Required Derating) , 20 - 90%RH (Non condensing)* | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, C-UL(CSA62368-1),EN62368-1, ANSI/AAMI ES60601-1, EN60601-1 3rd* |
Conducted Noise | Complies with FCC Part15 classB, VCCI-B, CISPR32-B, EN55011-B, EN55032-B | |
High Attenuation | Complies with IEC61000-3-2 * | |
Others | Dimensions (WxHxD) | 89×41×152mm [3.50x1.61x5.98 inches] (without terminal block and screw) |
Weight | 840g max | |
Cooling Method | Forced cooling (internal fan) | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Category | Part Number | Description | DXF | |
---|---|---|---|---|
Harness |
H-PA-14 | Harness for serial operation. | - | |
H-PA-15 | Harness for parallel operation and N+1 parallel redundancy operation. | - | ||
H-PA-16 | Harness for parallel operation of mater-slave. | - | ||
H-SN-48 | Harness for using all functions of CN1 and CN2. | - | ||
H-SN-49 | Harness for using all functions except remote sensing of CN1 and CN2. | - | ||
H-SN-50 | Harness for using all functions of CN3. | - | ||
H-SN-51 | Harness for using all functions of CN4. | - | ||
H-SN-52 | Harness for using example remote ON/OFF circuit C. | - | ||
H-SN-53 | Harness for using in slave setting of mater-slave operation. | - | ||
H-SN-54 | Harness for using in effective setting of external output voltage adjustment. | - | ||
H-SN-66 | Harness for using PMBus communication(for -I option). | - | ||
Communication converter |
CR-PC-1 | This is a unit to convert Extended UART signal to RS232 signal mutually. | - | |
CR-PC-2 | This is a unit to convert Extended UART signal to RS485(Modbus-RTU) signal mutually. | - |