Warranty Period | 10-year (Refer to Instruction Manuals) |
---|
When remote ON/OFF is not used, short RC and -Vin.
Features of MGW301212
• Industry Standard 1"X2"• 6 sided shield
• I/O isolation voltage DC1,500V (1 minute)
• Built-in overcurrent protection circuits (recovers automatically)
• Built-in overvoltage protection circuits
• High reliability : not built-in aluminum and tantalum electrolytic capacitor
Ordering Information and Options
MG(1) W(2) 30(3) 24(4) 05(5) - □(6)
(1) Series name(2) Dual output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
G: Capacitor between Input and Output is removed.
R: with Remote ON/OFF
(Positive logic control)
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | DC9 - 18V | |
Output | Wattage | 30W |
Voltage/Current | ±12V (+24V) 1.25A | |
Adjustable Voltage Range | - | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | Works over 120 to 160% of rating (Total of +V and -V) | |
Remote ON/OFF | Provided (Negative logic L: ON, H: OFF) | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -40 to +85℃, 20 to 95%RH (Non condensing) (Required Derating) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL, EN62368-1 |
Conducted Noise | - | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 25.4x9.9x50.8mm [1x0.39x2 inches] |
Weight | 40g max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 10-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |