Warranty Period | 5-year |
---|
Features of BRDS100
• Small size and high efficiency non-isolated DC-DC converter.• Wide input voltage 4.5V to 14.0V.
• Fast transient respoce by Robust control.
• Built-in remote ON/OFF, Power good, Start-up sequence.
• Built-in overcurrent and thermal protection (auto recovery type) functions.
• PMBus interface for programming, margining, and telemetry.
Ordering Information and Options
BRD(1) S(2) 60(3) S(4)- □(5)
(1) Series name
(2) Single output
(3) Output current
40: 40A
60: 60A
100: 100A
120: 120A
150: 150A
(4) Type
Blank: Standard type
S: Small type (only 60A)
(5) Optional
R: Positive logic remote on/off
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | DC4.5 - 14.0V | |
Output | Voltage/Current | 1.2V 100.0A |
Adjustable Voltage Range |
Adjustable by external resistor 0.7 - 2.0V |
|
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating (auto recovery type) |
Overvoltage Protection | - | |
Remote ON/OFF | Available Negative logic L: ON, H: OFF | |
Remote Sensing | Available | |
Others | PMBus communication | |
Operating Temperature/Humidity | -40 to +85℃, 20 - 95%RH (Non condensing) * | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , EN62368-1 |
Conducted Noise | - | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 38.0x8.5x27.7mm [1.5x0.33x1.09 inches] |
Weight | 22g max | |
Cooling Method | Convection/Forced air | |
Warranty Period | 5-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.