1. Output voltage setting
Output voltage setting means a range of output voltage set in the factory when product is shipped.
Output voltage is set to rated input voltage at rated load.
2. Output voltage accuracy
Output voltage accuracy means total output voltage fluctuation which is sum of line regulation, load regulation and temperature regulation.
Following shows formula of output voltage accuracy.
e.g) Output voltage accuracy of PCA600F-24
Voltage accuracy ΔV = ± (Line regulation + Load regulation + Temperature regulation) ÷ 2
= ± (96mV + 150mV + 240mV) ÷ 2
= = ± 243mV
= ± (96mV + 150mV + 240mV) ÷ 2
= = ± 243mV
Technical Product-related Inquires
e-mail:support@cosel.co.jp