Our Three-phase/Three-wire type EMI Filter can be used for Single-phase input.
Attenuation characteristics at three-phase and single-phase are shown below (ex. TAC-30-683), and confirmed that there is no big difference between them.
Rated input voltage of Three-phase EMI filter is AC500V, but it can be used for AC100V or AC200V input as well.
Three-phase input Attenuation Characteristics
(Measurement diagram: See Fig.1 and Fig.2)
Single-phase input Attenuation Characteristics
(Measurement diagram: See Fig.3 and Fig.4)
Please evaluate adequately in your equipment before use.
Three-phase input attenuation measurement diagram
Fig.1 Differential mode attenuation measurement diagram
Fig.2 Common mode attenuation measurement diagram
Single-phase input attenuation measurement diagram
Fig.3 Differential mode attenuation measurement diagram
Fig.4 Common mode attenuation measurement diagram
Technical Product-related Inquires
e-mail:support@cosel.co.jp