Warranty Period | 5-year (Refer to Instruction Manuals) |
---|
*This product is not available in Japan.
Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of WMA100F-24
・For medical electric equipment(ANSI/AAMI ES60601-1, EN60601-1 3rd)
・Medical Isolation Grade 2MOPP
・4kV isolation
・Low-profile
・Economical design
Ordering Information and Options
WM(1) A(2) 100(3) F(4) - □(5) - □(6)
(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
C:With Coating
G:Low leakage current
J1:VH(J.S.T.)connector type
J4:EP(Tyco)connector type
T1:Horizontal terminal block
See 5.1 in Instruction Manual.
Recommended EMI Filters
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 ~ 264V 1Φ | |
Output | Wattage | 103.2W |
Voltage/Current | 24V 4.3A | |
Adjustable Voltage Range | 21.60 ~ 26.40V | |
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | 27.60 ~ 33.60V | |
Remote ON/OFF | - | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -20 to +70℃ (Required to Derating) , 20 - 90%RH (Non condensing) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) |
UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, ANSI/AAMI ES60601-1, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), EN60601-1 3rd, EN61558-2-16 (OVC III), Complies with IEC60601-1-2 4th Ed. |
Conducted Noise | Complies with CISPR32 (EN55032) class B | |
High Attenuation | Complies with IEC61000-3-2 class A | |
Others | Dimensions (WxHxD) | 30×97×129mm |
Weight | 300g max | |
Cooling Method | Convection | |
Warranty Period | 5-year (Refer to Instruction Manuals) |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data | ||
---|---|---|
CAD Data | DXF | |
3D CAD Data | STEP | |
IGES |
- * For another documents aren't listed, please feel free to contact to a Cosel representative.